3) Equipment Connection / Procedure
Input
Input
Connection Point
* Open soldering pad IF.
VHS
HQ
AV
VCR
Jack
BOTTOM VIEW
TP5
R200
Vcc2 Voltage Setting
Set
Output
TP1
Input
Adjust
Signal
Connection
VR100
Contrast Adjustment
PLAY
VR300
Oscilloscope
Color bar
— 5 —
TP3
TP2
Pad IF
Voltmeter
Output
Output
Point
Adjust for 4.00 ± 0.02V
TP1
Voltmeter
reading on voltmeter.
Set
Input
Output
AV-C1
TP5
cord
Adjust step form wave to read
TP5
0.8 ± 0.05 Vp-p.
Adjust for
Oscilloscope