POWER SUPPLY VCC2 VEE1 T100 D115 LC12U-21 DC 6V VCC7 VCC6 Q102 from IC400 D116 L101 C151 Vref D117 R104 C152 Q100 D118 Q101 Fig. 3 The power supply consists of DC-DC converter, and causes the voltages to be output as shown in Table - 2. Name Voltage Function...
ADJUSTMENT Linear PCB 1) Items to Be Adjusted: Item Measuring Instrument VCC2 voltage setting Voltmeter Contrast adjustment TV signal generator, Pattern generator, Oscilloscope AGC adjustment TV signal generator, Pattern generator, IF levelmeter 2) Adjustment and Test Point Locations: TOP VIEW VR100 —...
Page 4
BOTTOM VIEW R200 Pad IF 3) Equipment Connection / Procedure Vcc2 Voltage Setting Voltmeter Output Input Input Input Output Output Adjust Adjust for Connection Point Signal Connection Point Adjust for 4.00 ± 0.02V VR100 Voltmeter reading on voltmeter. Contrast Adjustment * Open soldering pad IF.
A/D PCB 1) Item to Be Adjusted: Item Measuring Instrument Clock adjustment Voltmeter 2) Adjustment and Test Point Locations: TOP VIEW VR700 3) Equipment Connection / Procedure Clock Adjustment Voltmeter Output Input Input Input Output Output Adjust Adjust for Connection Point Signal Connection Point...