1-4. INDOOR FAN CONTROL

1. Fan speed
(Table 2 : Indoor Fan Speed)
AU *G18LVLB
Operation mode
Air flow mode Speed (rpm)
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Dry
Auto
S-Lo
AU *G36LRLE
Operation mode
Air flow mode Speed (rpm)
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Dry
S-Lo
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(Hi > Me, Me > Lo, Lo > Quiet, Quiet > Soft Quiet)
AR *G18LLTB
(Normal static pressure: 25Pa)
Operation mode
Air flow mode Speed (rpm)
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Dry
Auto
S-Lo
AR *G30/ 36LMLE
(Normal static pressure: 47Pa)
Operation mode
Air flow mode Speed (rpm)
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
Cooling
Hi
Fan
Me
Lo
Quiet
Dry
S-Lo
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(High > Med, Med > Low, Low > Quiet, Quiet > Soft Quiet)
AU *G22/ 24LVLA
Operation mode
830
Heating
770
730
630
500
400
Cool air prevention
730
Cooling
630
Fan
540
460
400
Dry
460
300
AU *G45LRLA
Operation mode
640
Heating
600
510
470
420
Cool air prevention
300
640
Cooling
510
Fan
470
420
300
Dry
420
270
AR *G22/ 24LMLA
(Normal static pressure: 35Pa)
Operation mode
1380
Heating
1300
1220
1140
Cool air prevention
1380
Cooling
1300
Fan
1220
1140
600
1140
Dry
600
AR *G45LMLA
(Normal static pressure: 30Pa)
Operation mode
Air flow mode Speed (rpm)
1270
Heating
980
790
630
Cool air prevention
Cooling
1130
Fan
980
790
630
630
Dry
420
01-04
Air flow mode Speed (rpm)
Hi
960
Me+
930
Me
880
Lo
740
Quiet
580
400
Hi
960
Me
850
Lo
650
Quiet
500
*Soft Quiet
400
Auto
500
S-Lo
300
Air flow mode Speed (rpm)
Hi
690
Me+
650
Me
610
Lo
550
Quiet
470
300
Hi
690
Me
610
Lo
550
Quiet
470
*Soft Quiet
300
Auto
470
S-Lo
270
Air flow mode Speed (rpm)
830
Hi
Me+
Me
700
600
Lo
550
Quiet
830
Hi
700
Me
600
Lo
550
Quiet
*Soft Quiet
350
550
Auto
350
S-Lo
Hi
1300
Me+
Me
1020
Lo
840
Quiet
670
Hi
1310
Me
1020
Lo
840
Quiet
670
*Soft Quiet
420
Auto
670
S-Lo
420
AU *G30LRLE
Operation mode
Air flow mode Speed (rpm)
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Dry
S-Lo
570
530
510
470
420
300
570
510
470
420
300
420
270