GE DigitalFlow DF868 Programming Manual page 55

Panametrics multipurpose ultrasonic liquid flowmeter
Hide thumbs Also See for DigitalFlow DF868:
Table of Contents

Advertisement

Slot X Analog Outputs
Programming Site Data
Complete the following steps to set up the
1. Use the [←] and [→] and
Output.
Note: The set up of output A is used as an example. Identical
procedures would be used to set up output B.
[F1]=OFF
2. Press
to disable output A and return to the previous
[F2]=0-20mA or [F3]=4-20 mA
prompt, or press
desired range for output A.
3. Use the [←] and [→] and
for the data source, as shown in Table 1-20 below
Table 1-20: Channel Options
Option
CH1
CH2
SUM
DIF
AVE
4. Use the [←] and [→] and
Output Measurement parameter, as shown in Table 1-21 below.
Table 1-21: Output Measurement Options
Option Bar Choice
=
[F1]
VEL
=
[F2]
VOLUM
=
[F3]
+TOTL
=
[F4]
-TOTL
→]
=
[
+ [F1]
MDOT*
→]
=
[
+ [F2]
+MASS*
→]
=
[
+ [F3]
-MASS*
→]
= POWER**
[
+ [F4]
→]
→]
= +ENRG**
[
+ [
+ [F1]
→]
→]
= -ENRG**
[
+ [
+ [F2]
→]
→]
=
[
+ [
+ [F3]
* Available only if
Available only if
**
Slot X
[F1]-[F4]
keys to select the desired
[F1]-[F4]
keys to select a Channel option
Description
Channel 1
Channel 2
CH1+CH2
CH1-CH2
(CH1+CH2)/2
[F1]-[F4]
keys to specify the desired
Description
Flow Velocity
Volumetric Flow
Forward Totalized Volume Flow
Reverse Totalized Volume Flow
Mass Flow
Forward Totalized Mass Flow
Reverse Totalized Mass Flow
Energy Flow Power
Forward Energy Flow
Reverse Energy Flow
Diagnostic
DIAG
Mass Flow (static)?
Energy Option = YES
March 2008
analog outputs:
to specify the
=
YES
1-47