mount the manifold to the mounting bracket. Do not forget to install
the o-ring flange seals in the recessed grooves on the block manifold
flange(s).
To verify direction of flow, look at the (+) and (-) signs on the
transducer tag. Plus(+) indicates high side (upstream) and (-)
indicates the low side (downstream), therefore flow is from (+) to (-).
If this causes the device to face the wrong direction, loosen the Allen
Head set screw on the neck of the device and with the hands turn
the unit clockwise until the unit is facing the correct direction. If the
unit gets tight before achieving the correct position, turn counter-
clockwise (no more than 360 degrees) until the correct position is
obtained; then re-tighten the set screw.