AEG HGB75420YM User Manual page 19

Table of Contents

Advertisement

9.2 Bypass diameters
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
9.3 Other technical data
Gas original:
TOTAL POW‐
Gas replace‐
ER:
ment:
Electric supply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
Appliance cate‐
II2H3+
gory:
Gas connec‐
R 1/2"
tion:
Appliance
3
class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Rapid
Semi-rapid
Auxiliary
WARNING!
This appliance does not
function with the existing gas
settings if installed in Malta.
Therefore, before connecting
the appliance it is essential
to change the nozzles
according to the type of gas
used according to the table
below.
G20 (2H) 20 mbar
G30 (3+) 28-30 mbar
G31 (3+) 37 mbar
NORMAL POWER
kW
4,0
2,95
1,85
1,0
Ø BYPASS 1/100 mm
57
52
35
28
11,65 kW
825 g/h
811 g/h
MINIMUM POWER
kW
1,4
0,75
0,6
0,33
ENGLISH
INJECTOR MARK
146
119°
92
70
19