Makita HR007G Instruction Manual page 22

Cordless combination hammer
Hide thumbs Also See for HR007G:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Turn the dial on the dust case three times after col-
lecting every 50,000 mm
vacuum performance declined.
3
NOTE: 50,000 mm
of dust equivalents to drilling
10 holes of ø10 mm and 65 mm depth.
► Fig.38: 1. Dust case 2. Dial
Disposing of dust
Optional accessory
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
CAUTION:
Be sure to wear dust mask when
disposing of dust.
CAUTION:
Empty the dust case regularly
before the dust case becomes full. Failure to do so
may decrease the dust collection performance and
cause dust inhalation.
CAUTION:
The performance of dust collection
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide. Failure to do so may cause dust inhalation.
1.
Remove the dust case while pressing down the
latch lever of the dust case.
► Fig.39: 1. Latch lever
2.
Lift the lock tab slightly outwards and open the
dust case cover.
► Fig.40: 1. Dust case cover 2. Lock tab
3.
Dispose of the dust, and then clean the filter.
► Fig.41
NOTICE:
When cleaning the filter, tap the case
of the filter gently by hand to remove dust. Do not
tap the filter directly; touch the filter with brush
or similar; or blow compressed air on the filter.
Doing so may damage the filter.
Blow-out bulb
Optional accessory
After drilling the hole, use the blow-out bulb to clean the
dust out of the hole.
► Fig.42
Using dust cup set
Optional accessory
Fit the dust cup set against the ceiling when operating
the tool.
► Fig.43
NOTICE:
Do not use the dust cup set when drill-
ing in metal or similar. It may damage the dust
cup set due to the heat produced by small metal
dust or similar.
3
of dust or when you feel the
NOTICE:
Do not install or remove the dust cup
set with the drill bit installed in the tool. It may
damage the dust cup set and cause dust leak.
WIRELESS ACTIVATION
FUNCTION
What you can do with the wireless
activation function
The wireless activation function enables clean and com-
fortable operation. By connecting a supported vacuum
cleaner to the tool, you can run the vacuum cleaner
automatically along with the switch operation of the tool.
► Fig.44
To use the wireless activation function, prepare follow-
ing items:
A wireless unit (optional accessory)
A vacuum cleaner which supports the wireless
activation function
The overview of the wireless activation function
setting is as follows. Refer to each section for detail
procedures.
1.
Installing the wireless unit
2.
Tool registration for the vacuum cleaner
3.
Starting the wireless activation function
Installing the wireless unit
Optional accessory
CAUTION:
Place the tool on a flat and stable
surface when installing the wireless unit.
NOTICE:
Clean the dust and dirt on the tool
before installing the wireless unit. Dust or dirt
may cause malfunction if it comes into the slot of the
wireless unit.
NOTICE:
To prevent the malfunction caused by
static, touch a static discharging material, such
as a metal part of the tool, before picking up the
wireless unit.
NOTICE:
When installing the wireless unit,
always be sure that the wireless unit is inserted
in the correct direction and the lid is completely
closed.
1.
Open the lid on the tool as shown in the figure.
► Fig.45: 1. Lid
2.
Insert the wireless unit to the slot and then close
the lid.
When inserting the wireless unit, align the projections
with the recessed portions on the slot.
► Fig.46: 1. Wireless unit 2. Projection 3. Lid
4. Recessed portion
22 ENGLISH

Advertisement

Table of Contents
loading

Table of Contents