Power amplifier output cables
Unshielded cables with a cross-section of 1.3mm
for the power amplifier output.
XLR audio input cable
Shielded pair cables with a cross-section of 0.3~0.5mm
external audio resource.
PIN
1
2
3
Dry contact input/output cables and related external equipment (optional)
The necessity of dry contact connections depends on the system situation. If the DCS and
external equipment, such as 3-wire volume controllers and 4-wire volume controllers, must be
connected through dry contacts, this equipment and the appropriate cables must be prepared
beforehand.
Noise detector (optional)
When needing to collect environmental noise and automatically regulate the volume of
broadcasts, a noise detector and appropriate cables must be prepared. For connecting X-
DCS2000/ X-DCS3000 with X-ND100, the maximum cable distance between the DCS and
noise detector is required to be no more than 1000m, and twisted pair cables with a cross-
section of 1.3mm
Monitoring module cable of end-of-line (optional)
If there is necessary to use monitoring module X-EOL to detect faults of speaker lines, users
need to connect monitoring module with X-DCS3000. The distance between monitoring
module and DCS should be less than 1000m, and twisted pair cables with a cross-section of
1.3mm

Packing List Inspection

Please check the external packages for intactness before unpacking them for content inspection.
Use the "Packing list" to check the package contents. Contact the carrier or supplier promptly in
case of any package or package content problems.
Type
GND(0V)
VCC(12V-24V, powered by an external
device)
Self-test port
When the DA output voltage is VCC
(12V-24V), the DA is being self-tested.
When the DA has no input voltage, the
DA is working normally.
Table 3 X-DCS3000 XLR Input Terminal Pin Definition Descriptions
Type
Grounding wire(Shielded layer of cable)
Hot end (Positive)
Cold end (Negative)
2
(wire gauge of 16AWG) must be used.
2
(wire gauge of 16AWG) must be used.