The pilot flame is lit automatically. Do not attempt to
manually light the pilot. If the appliance does not turn on
when the thermostat is set several degrees above room
temperature, follow these instructions:
1. Set the thermostat to its lowest setting to reset the
safety control.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn
clockwise
to OFF.
5. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow step 3 in the Warning in
the Instructions To The Homeowner section. If you do not
smell gas, continue with the next step.
6. Turn the gas control knob counterclockwise
PILOT.
7. Turn the gas control knob counterclockwise
ON.
8. Replace the gas control access panel.
9. Reconnect all electric power to the appliance.
10. Set the thermostat to the desired setting.
11. If the appliance does not turn on, set the gas control
knob to OFF and contact a qualified service technician for
assistance.

TURNING OFF THE APPLIANCE

VACATION SHUTDOWN—Set the thermostat to the
desired room temperature while you are away.
COMPLETE SHUTDOWN—Push in the gas control knob
slightly and turn clockwise
Appliance will completely shut off. Follow the In-
to
structions to the Homeowner above to resume normal
operation.
to
9
to OFF. Do not force.