Hitachi Advanced Server DS220 Hardware Guide This guide provides the system overview and specifications for Hitachi Advanced Server DS220, including hardware descriptions, ports, network interface cards, and LEDs. MK-97HAS011-00 April 2018...
Page 2
Licensee may not make any other copies of the Materials. "Materials" mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
ABLE OF ONTENTS ABLE OF ONTENTS About the System Introduction ............1 System Features.
Page 4
ONVENTIONS Conventions Several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files.
Page 5
RECAUTIONARY EASURES Precautionary Measures Read all caution and safety statements in this document before performing any of the instructions. To reduce the risk of bodily injury, electrical shock, fire, and equipment dam- age, read and observe all warnings and precautions in this chapter before installing or maintaining your system.
Page 6
RECAUTIONARY EASURES Table 1: Warning and Cautions (Continued) The enclosure is designed to carry only the weight of the system sled. Do not use this equipment as a workspace. Do not place additional load onto any equipment in this system. Indicates two people are required to safely handle the system.
Page 7
RECAUTIONARY EASURES Equipment Handling Practices Reduce the risk of personal injury or equipment damage: Conform to local occupational health and safety requirements when moving and lifting equipment. Use mechanical assistance or other suitable assistance when moving and lifting equipment.
Page 8
RECAUTIONARY EASURES Rack Mount Warnings The following installation guidelines are required by UL for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable support to prevent it from tip- ping when your system or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.
Page 9
RECAUTIONARY EASURES Electrostatic Discharge (ESD) CAUTION! CAN DAMAGE DRIVES BOARDS AND OTHER PARTS E RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN WORKSTATION F ONE IS NOT AVAILABLE PROVIDE SOME PROTECTION BY WEARING AN ANTI STATIC WRIST STRAP ATTACHED TO CHASSIS GROUND ANY UNPAINTED METAL SURFACE ON YOUR SERVER WHEN HANDLING PARTS...
Page 10
RECAUTIONARY EASURES ified in this manual. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in non-compliance with product regulations in the region(s) in which the product is sold. System power on/off: To remove power from system, you must remove the system from rack.
Page 11
RECAUTIONARY EASURES The system is designed to operate in a typical office environment. Choose a site that is: Clean and free of airborne particles (other than normal room dust). Well ventilated and away from sources of heat including direct sunlight. ...
Page 12
About the System This guide provides the system overview and specifications for Hitachi Advanced Server DS220, including hardware descriptions, ports, network interface cards, and LEDs.
BOUT THE YSTEM NTRODUCTION Introduction This guide provides the system overview and specifications for Hitachi Advanced Server DS220, including hardware descriptions, ports, network interface cards, and LEDs. System Features The system comprises a 2U/30.7” long chassis. Major features include: ®...
Page 14
BOUT THE YSTEM YSTEM EATURES Table 1: System Specifications (Continued) PECIFICATIONS ESCRIPTION Total slots: 24 Memory type: DDR4 2666 MT/s RDIMM Memory Memory size: 8GB, 16GB, 32 GB* *More options refer to the AVL Onboard (Intel® C621 / C624 / C628): ...
BOUT THE YSTEM YSTEM EATURES SKU information 3.5” SKU Overview 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5”...
Page 18
BOUT THE YSTEM YSTEM EATURES 3.5” All SATA/SAS - SKU1 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5” SATA/ SAS 3.5”...
BOUT THE YSTEM OUR OF THE YSTEM A Tour of the System System Overview The server is available as a 3.5” storage drive configuration. The 3.5” storage drive configuration system overview is displayed in the following image: Figure 1. 3.5” Storage Drive System Component Overview Table 2: Component Overview ESCRIPTION Front control panel...
BOUT THE YSTEM YSTEM RONT Table 2: Component Overview (Continued) ESCRIPTION Asset tag Record serial number or other important information 3.5” storage drive tray Housing up to twelve 3.5” storage drive VGA port Connect to display device (Display Priority: First; one device one time) Mainboard System mainboard PSU assembly...
Page 22
BOUT THE YSTEM YSTEM RONT Table 3: Front Panel View (Continued) ESCRIPTION Housing up to twelve 3.5” storage drive: All SATA/SAS SKU HDD0~HDD11 support SAS/SATA HDD/SSD 3.5” storage drive tray Tiered SKU HDD0~HDD7 support SAS/SATA HDD/SSD; HDD8~HDD11 support SAS/SATA HDD/SSD or 2.5” NVMe SSD* Two server handles used for pulling the system out of the rack CAUTION! Handle...
Front Conrtol Panel (FCP) BOUT THE YSTEM Front Control Panel (FCP) Figure 4. Front Control Panel and Connectors Table 6: Front Control Panel Descriptions ESCRIPTIONS Power on / off Power button with Blue on - S0 system power on; Off - S5 system power off Reset button Soft reset system function Provides critical and non-critical failure notification...
BOUT THE YSTEM YSTEM System Rear View HDD0 HDD1 Figure 5. System Rear View Table 7: System Rear View EATURE ESCRIPTION Power sub-system Main power supply unit (PSU1). See Power Sub-System on page 15. System I/O ports See System Rear I/O on page 14 Expansion slot Support OCP 2.0 mezzanine card installation (CPU0) Power sub-system...
BOUT THE YSTEM YSTEM System Rear I/O Figure 6. System Rear I/O Table 9: System Rear I/O Descriptions ESCRIPTIONS Dedicated NIC BMC dedicated RJ45 connector Maximum display resolution: 1920x1200 32bpp@60Hz VGA port (reduced blanking) (Display Priority: First; one device one time) COM A port DB9 port (Serial_A) for debug or terminal concentrator USB 1 port;...
BOUT THE YSTEM YSTEM Power Sub-System PSU LED Figure 7. PSU to Mainboard Module Description A single power supply unit (default) is supplied in the system. A secondary PSU is available for redundancy functionality. Table 10: Power Supply Units by Model AC I NPUT 2 x 800W and 1200W Titanium/Platinum...
LED S TATUS ESCRIPTIONS BOUT THE YSTEM LED Status Descriptions Front Control Panel LEDs For location of the FCP, see System Front View on page 9. Power LED Status LED ID LED Figure 8. Front Control Panel LEDs Table 12: Front Control Panel LEDs Behavior LED D OLOR ONDITION...
LED S BOUT THE YSTEM TATUS ESCRIPTIONS Table 13: RJ45 LED Descriptions ONDITION CTIVITY Unplugged 1G active link On amber Blinking green 100M active link On green Blinking green 10M active link Blinking green Storage Drive LEDs Rear 2.5” Storage Drive LED Status Behavior Active LED Status / Fault LED Figure 10.
Page 30
LED STATUS DESCRIPTIONS BOUT THE YSTEM Front 3.5” Storage Drive LED Status Behavior Status / Fault LED Active LED Figure 11. 3.5” Storage Drive LED Identification The following LED behavior table represents LED conditions. Table 15: 3.5” Storage Drive LED Status Behavior OLOR ONDITION ESCRIPTIONS...
Page 31
Hitachi Vantara Corporate Headquarters Regional Contact Information 2845 Lafayette Street Americas: +1 866 374 5822 or info@hitachivantara.com Santa Clara, CA 95050-2639 USA Europe, Middle East and Africa: +44 (0) 1753 618000 or info.emea@hitachivantara.com www.HitachiVantara.com Asia Pacific: +852 3189 7900 or info.marketing.apac@hitachivantara.com...