Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 126

Simodrive 611 series drive converter
Table of Contents

Advertisement

10.04
02.12
05.01
Table 5-1
Power modules in the 1–axis version
j
j
6SN112
–1AA0
3 internal cooling
1)
4 external cooling
Mounting frame external
cooling 6SN1162–0BA04–
Type of cooling
For operation of induction motors
Nominal current I
n
Current for S6–40% I
S6–40%
Peak current I
max
Inverter pulse frequency f
0
Derating factor X
L
Power loss, total P
Vtot
Power loss, internal P
Vint
Power loss, external P
Vext
For operation of synchronous motors
Nominal current I
n
Peak current I
max
Inverter pulse frequency f
0
Derating factor X
L
Power loss, total P
Vtot
Power loss, internal P
Vint
Power loss, external P
Vext
General technical data for the regulated infeed
Input voltage
V DC
Maximum output voltage
5)
Minimum motor current I
min
Transistor limit current
Efficiency
Module width
Weight, approx.
Maximum air flow of fan
(volumetric flow, unobstructed
flow per fan)
m
Motor connection
1) For a module width of 300 mm with external cooling, mounting frames are required that must be separately ordered.
The fan assembly required to mount the built–on fan is included in the scope of supply of the mounting frame.
The built–on fan must be separately ordered! Mounting frames are also available for smaller module widths. However,
these are not required if openings are cut out in the rear cabinet panel for the module heatsinks as shown
in this Configuration Manual.
j
j
2) For 6SN1123–1AA0
–0JA
6SN1162–0BA02–0AA2 is required.
3) Is applicable for internal cooling. For external cooling with mounted fan 2) 400 m3/h
4) True for induction motors and applies to the no–load current.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
0HA
j
0AA
j
0BA
j
0CA
0AA
0FA
j
Non–
ventilated
A
3
5
8
eff
A
3
5
10
eff
A
3
8
16
eff
kHz
%
50
W
30
40
74
W
12
16
29
W
18
24
45
A
3
5
9
eff
A
6
10
18
eff
kHz
%
55
W
35
50
90
W
14
19
35
W
21
31
55
Regulated: 600 V or 625 V DC, unregulated: U
V
eff
A
0.6
1.1
1.8
A
8
15
25
mm
50
kg
6.5
19
3
/hr
Connectors
j
j
/0KA
and 6SN1124–1AA0
–0FA
5 Power Modules
5.3 Technical data
j
0DA
j
0LA
j
0EA
j
0FA
0BA
0CA
j
j
j
Fan
24
30
45
60
32
40
60
80
32
51
76
102
3.2
55
50
260
320
460
685
89
32
19
30
171
288
441
655
18
28
42
56
36
56
64
112
4
50
190
300
460
645
65
30
25
25
125
270
435
620
=U
DC link
U
= U
/1.4
a_max
DC link
3.6
5.7
8.5
11
50
80
108
160
0.98
100
150
9.5
13
3)
22
56
2x56
2x56
2x51
Terminals
j
j
j
/–0JA
/–0KA
, the built–on fan
j
0JA
j
0KA
j
0EA
j
85
120
200
110
150
250
127
193
257
55
850
1290
2170
100
190
325
750
1100
1845
70
100
140
140
100
210
55
730
1300
1910
90
170
250
640
1130
1660
 1.35
Supply
14
21
28
200
300
400
2)
300
26
28
2)
5-125
5