Chapter 2 Configuring and Upgrading the System
5.3.3 Replacing 2.5-inch Hard Disk Drive
Follow the steps below to remove the failed hard disk drive. The hard disk drive is replaced with a new disk with
the server powered on.
(1)
Replacing the Hard Disk Drive
1. Locate the failed hard disk drive.
When a hard disk drive fails, the DISK ACCESS LED on the hard disk drive's handle lights amber.
2. Remove the failed hard disk according to Chapter 2 (1.3 Replacing Failed Hard Disk Drives).
3. Wait at least 15 seconds. Then, follow the steps in Chapter 2 (5.3.1 Installing 2.5-inch Hard Disk Drive)
to install a new hard disk drive.
4. Restore the redundant configuration.
See Chapter 2 (1.3 Replacing Failed Hard Disk Drives).
Express5800/R310g-E4, R320g-E4, R320g-M4 Maintenance Guide (Windows)
154
See Chapter 2 (5.1.3 Precautions for installing/replacing optional devices) and
Important
Chapter 1(1.8 Anti-static Measures) in Safety Precautions and Regulatory Notices
before starting installing or removing options.
Note
The hard disk drive to be installed for replaced must have the same specifications as
its mirroring hard disk drive.
Use unsigned hard disk drive for replacement. To use the signed disk, recover the
duplex configuration according to Chapter 2 (1. Hard Disk Drive Operations) after
formatting the disk physically.
For details about the physical format, see Chapter 3 (3.3 Physical Formatting of the
Hard Disk Drive).