Getting Started

1.7 Getting Started
The following is a brief summary of the minimal steps involved in bringing an NFW-50X on-line:
Install Backbox and Main Circuit Board (refer to "Mounting the Backbox" on page 20)
Address and Install Intelligent Devices (refer to the FireWarden/ONYX SLC Wiring Manuals)
Enter Autoprogramming (refer to "Autoprogram" on page 49)
Resolve Programming Conflicts
Go to Point Program to Enter Specific Data (refer to "Point Program" on page 50). Use the right and left arrow keys to navigate
between devices.

1.8 Telephone Requirements and Warnings

1.8.1 Telephone Circuitry
Ringer Equivalence Number (REN) = 0.3A
AC Impedance: 10.0 Mega Ohm
Complies with FCC Part 68
Mates with RJ31X Male Connector
Supervision Threshold: loss of phone line voltage for 2 minutes
The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone
line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not
exceed five (5.0). To be certain of the number of devices that may be connected to the line as determined by the total RENs, contact the
telephone company to determine the maximum REN for the calling area.
Before connecting the control panel to the public switched telephone network, the installation of two RJ31X jacks is necessary. If trouble
is experienced with this equipment, for repair or warranty information, please contact:
Manufacturer:
Product Model Number: NFW-50X
FCC Registration Number: US:1W6AL03AEVOLX
Ringer Equivalence: 0.3A
NOTE: This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the inside of the FACP
door is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number
must be provided to the telephone company.
Alarm dialing equipment must be able to seize the telephone line and place a call in an emergency situation. It must be able to do this
even if other equipment (telephone, answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dial-
ing equipment must be connected to a properly installed RJ31X jack that is electrically in series with and ahead of all other equipment
attached to the same telephone line. If there are any questions concerning these instructions, consult the telephone company or a quali-
fied installer about installing the RJ31X jack and alarm dialing equipment. Refer to "CELL-MOD/CELL-CAB-N" on page 29 for an
illustration of the proper installation of this equipment.
Important! The DACT must not be used to dial a phone number that is call-forwarded.
1.8.2 Telephone Company Rights and Warnings
The telephone company, under certain circumstances, may temporarily discontinue services and/or make changes in its facilities, ser-
vices, equipment or procedures which may affect the operation of this control panel. However, the telephone company is required to give
advance notice of such changes or interruptions.
If the control panel causes harm to the telephone network, the telephone company reserves the right to temporarily discontinue service.
Advance notification will be provided except in cases when advance notice is not practical. In such cases, notification will be provided
as soon as possible. The opportunity will be given to correct any problems and to file a complaint with the FCC if you believe it is neces-
sary.
DO NOT CONNECT THIS PRODUCT TO COIN TELEPHONE, GROUND START, OR PARTY LINE SERVICES.
When the control panel activates, premise phones will be disconnected.
Two separate phone lines are required. Do not connect both telephone interfaces to the same telephone line.
The control panel must be connected to the public switched telephone network upstream (as first device) of any private telephone system
at the protected premises.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part
68 rules and requirements adopted by ACTA. This equipment is designed to be connected to the telephone network or premises wiring
using a compliant RJ31X male modular plug and compatible modular jack that is also compliant.
NFW-50X Manual — P/N LS10129-001NF-E:C 7/25/2018
Honeywell International, Inc.
12 Clintonville Road
Northford, CT 06472
(203) 484-7161