Honeywell SAT-IDP Series User Manual page 30

Table of Contents

Advertisement

GPS
Channels
Time To First Fix (Typical)
Cold start:
Hot start
Accuracy (SA Off)
Position (CEP, 2D):
Altitude
Dynamic capability
Velocity:
Acceleration:
Maximum update interval
Control and Monitoring
Interface
Baud rate
Parity/data bits/stop bits
Data Interfaces
5 x I/O
1 x Open drain output
Power Consumption (Typical @ 12V)
Sleep
Receive (including GPS)
Transmit
Power Supply Voltage
Voltage range
MAN-0077
50
<30s
<3s
2.5m (CEP, 2D)
Maximum 50000m
Maximum 500m/s
</= 4g
1s
Asynchronous serial RS232
4800 or 9600 bps
N,8,1
Individually configurable as;
High voltage digital input (32V max) with falling edge interrupt
capability
Switch input (internal pull-up used with external switch to ground)
Digital input (TTL) with falling edge interrupt capability
Analogue input (12 bit ADC, 0 to 3.3V)
Digital output (3.3V, 50µA typical)
250mA max. sink current
0.5W
2.3W
10W
9.6V to 32V 'smoothed' DC