Chapter 3 - Installation; Power Requirements; Cable - Honeywell SAT-IDP Series User Manual

Table of Contents

Advertisement

Chapter 3 - Installation

IMPORTANT: Installation and service should only be carried out by suitably
qualified service personnel.
Local working practices and regulations for wiring and installations must be adhered to at all times.

3.1 Power Requirements

The equipment is powered from an external DC supply of 9.6V to 32V. The DC supply must be capable of
providing a maximum VA of 9.6W, for example 1A @ 9.6V or 0.3A @ 32V.
External power is connected via the 12-way connector (see page 18 for connector details and pin connections)
When installing the SAT-IDP, adequate circuit protection must be provided as required by local regulations.
IMPORTANT: If connecting to an external battery, the SAT-IDP requires an
external fast acting fuse connected in series with the +ve supply at the battery end
of the cable.
Input voltage
9.6 to 32 VDC
IMPORTANT: If an external AC/DC Adaptor is used to power the equipment, it
must meet the requirements of EN 60950-1. The output of the Adaptor must also
meet the SELV limits of EN 60950-1.

3.2 Cable

It is recommended that cable routing is planned and operation tested before committing to a permanent
installation. The maximum cable diameter must not exceed 7mm, the maximum allowed by the terminal
connector.
MAN-0077
Fuse rating
2A
Honeywell Global Tracking Ltd
Minimum wire gauge
24 AWG (7/0.2)
8