Download Print this page

Adapti On To Different Types Of Gas - Omega OG60WA Installation & Operating Instructions Manual

Advertisement

CHANGING GAS INJECTORS-CONVERSI ON OF GAS TYPE
Your cooktop has been manufactured for operation on the gas type marked on
the hob/carton.
In some cases, it may be necessary to convert to convert the burners for use
with another type of gas.
Replacement injectors are supplied with the appliance or they are
1)
available from Omega Appliances or it's agents.
All such work MUST be carried out by an Authorized Person.
2)
Isolate the electrical supply from the appliance.
3)
Remove burner cap and burner skirt.
4)
Remove injectors - figure 4 (use a 7mm tube spanner).Replace in or­
5)
der with new injectors (make sure the correct size injectors are used).See data on
underside of hob for size or refer to page 10 for chart.
The regulator is required to be fitted and adjusted for Natural Gas and
6)
removed for ULPG.
Re-assemble, test for leak with a soapy solution (bubbles) and
7)
reconnect power.
Low Flame Adjustment
Ignite the burners
Remove the knobs, because the screws are accessible down the shaft
of the gas valve.
Using a small screwdriver (2mm), adjust the by-pass screw (Fig.5) until
the flame of the burner comes down to the minimum.
When the flame has a length of at least 4mm, the gas is well
Distributed.
Make sure that the flame does not go out when passing from the maximum
Position.
10

Hide quick links:

Advertisement

loading