Download Print this page

Hitachi 115VIF-3 Instruction Manual page 6

For crane & hoist pendant applications

Advertisement

AC Input Wiring – Connecting the Pendant to the 115VIF-3 Interface Board
Connect the pendant 115 VAC input wiring to the terminals marked AC1 through AC5 on the 115VIF-3, with
NEU (neutral of the pendant control signals) as their common terminal. AC1 thru AC5 are connected to the
HOT side of the pendant control signals, coming from the pendant's pushbutton contacts. The board's AC input
terminal functions are as follows:
INPUT
AC1
(Note 1)
AC2
(Note 1)
AC3
AC4
(Note 2)
Up over-travel photo limit (NC sensor
AC5
input; open-circuit stops/prevents UP
(Note 2)
motion – only DOWN motion is possible)
AC6
NC
Not used/no connection
IN
GND
Note 1:
Inputs AC1 and AC2 functions are symmetrical with respect to direction in traverse applications. In hoist applications, however, AC1 must be
used for UP and AC2 must be used for DOWN.
Note 2:
AC4 and AC5 inputs are intended to be used with over-travel limit sensors. These are secondary safeties, over and above N.C. limit switches
that would be wired in series with the AC1 and AC2 pendant inputs. They are "fail-safe" inputs, for use with N.C. type sensors. In this way, a
cut wire will have the same effect (inhibited of motion) as a sensor being triggered.
Note 3:
AC4 may also be used for 3-Step Hoist Control. Refer to page 11.
Important: If you will not use the
AC4 or AC5 for end-of-travel safety
inputs, then both these inputs must
be jumpered to the pendant HOT
supply, otherwise motor rotation will
be prevented. When end of travel
limit switches ARE used, they should
be wired in place of these jumpers.
Figure 2-2,
Pendant AC
Wiring
HOIST
Up PB
Down PB
nd
Increase/2
speed
Jumpered to HOT
(Note 3)
Page 6 of 16
TRAVERSE
Forward/Left PB
Reverse/Right PB
Increase/2
Horizontal over-travel limit (NC sensor input;
open-circuit forces inverter to MIN speed)
Jumpered to HOT
Not used/no connection
Chapter 2
nd
speed
PENDANT

Advertisement

loading

This manual is also suitable for:

Sj200 seriesSj700 series