NX-320E REMOTE POWER SUPPLY
Installation and Startup

Advertisement

Table of Contents
loading

Summary of Contents for GE NetworX Series

  • Page 1  NetworX Series NX-320E REMOTE POWER SUPPLY Installation and Startup...
  • Page 2 GE Interlogix, Gladewater, Texas, USA. This document contains proprietary information of GE Interlogix, USA and is furnished to its customer solely to assist that customer in the installation, testing, operations, and/or maintenance of the equipment described.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS GENERAL DESCRIPTION ......................4 ORDERING INFORMATION ......................4 III. UNDERWRITERS LABORATORIES INFORMATION ..............4 ENCLOSURE DIAGRAM......................5 BATTERY CALCULATION TABLE....................5 TERMINAL DESCRIPTIONS ......................6 VII. WIRING REQUIREMENTS......................6 VIII. LAYOUT ............................7 ADDRESSING ..........................8 ENROLLING ..........................8 UNDERSTANDING THE LEDS....................8 XII. PROGRAMMING .........................9 I.A. USING THE LED KEYPAD....................9 I.B.
  • Page 4: General Description

    NX-320E, is 2500 feet. Additionally, the maximum total wire run from the power supply module to all outgoing devices is 2500 feet. It is not recommended that multiple power supply modules be connected in series (cascaded). ORDERING INFORMATION Please refer to the GE Interlogix product catalog for warranty details. PART # DESCRIPTION NX-320E...
  • Page 5: Enclosure Diagram

    ENCLOSURE DIAGRAM Inside the can, several 2-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules. Notice that the insertion points have two sizes of holes -- a larger hole and a smaller hole. Diagram 1: The black plastic PCB guides are grooved on one edge where the PC Board will be seated.
  • Page 6: Terminal Descriptions

    TERMINAL DESCRIPTIONS Table VI:1 Terminal Description Connect to the NX-8 / NX-8E / NX-8-CF control panel Data terminal. This terminal is the DATA incoming data-signaling terminal to the power supply module. The maximum total wire run from the control panel to all devices, including the NX-320E is 2500 feet. Connect to the NX-8 / NX-8E / NX-8-CF control panel COMMON terminal.
  • Page 7: Layout

    LAYOUT VIII. NX-320E Power Supply...
  • Page 8: Addressing

    ADDRESSING The first thing that must be decided is the address of this particular power supply. This is the address that will be selected when programming the module. To set the address, use the table below. Dip Switch 4 is used to disable the Tamper feature (“On = enabled / “Off” = disabled). Table IX:1 Dip switch 3 Address...
  • Page 9: Programming

    PROGRAMMING XII. USING THE LED KEYPAD I.A. ACTION RESULT 1. Entering the Program Mode Enters the Program Mode. Stay, Chime, Exit, Bypass & Cancel LEDS will flash. If the "Go To Program Code" is valid, the "Service" LED will flash and Go To Program Code the 5 function LEDs will illuminate steady.
  • Page 10: Using The Lcd Keypad

    To Exit a Location: Exits from this location. The “Ready” LED will extinguish. The "Armed" LED will illuminate waiting for a new programming location to be entered. To Review The Data: The Armed LED will flash. If the location number is valid, the "Armed" [location] # LED will extinguish, the "Ready"...
  • Page 11: Location 0

    Example: If the numerical data to be programmed in a location is "66", press [6]-[6] on the keypad. The LED=s for Zone 2 and Zone 7 will become illuminated indicating 66 is in that location (2 + 64 = 66). Once the data is programmed, press [r] to enter the data and advance to the next segment of that location.
  • Page 12: Location 1 Programming Special Features For Output A

    LOCATION 1 PROGRAMMING SPECIAL FEATURES FOR OUTPUT A (2 segments of feature selection data) Segment 1 selects the following special conditions: 1 = "On" if output should time in minutes; "Off" if output times in seconds. 2 = "On" if output should latch until a code is entered; “Off” for timed. 3 = "On"...
  • Page 13: Location 4 Programming The Event & Time For Output C

    Segment 2 selects the following partitions: 1 = "On" if the event should activate when it occurs in Partition 1. 2 = "On" if the event should activate when it occurs in Partition 2. 3 = "On" if the event should activate when it occurs in Partition 3. 4 = "On"...
  • Page 14: Codes 1-10 Output Enable

    LOCATION 8 CODES 1-10 OUTPUT ENABLE (10 segments of feature selection data) When activating outputs with a user code (event #30), location 8 can be used to restrict certain codes from activating certain outputs. Location 8 contains 10 segments. Segment 1 corresponds to user 1; Segment 10 corresponds to user 10.
  • Page 15: Codes 61-70 Output Enable

    LOCATION 14 CODES 61-70 OUTPUT ENABLE (10 segments of feature selection data) When activating outputs with a user code (event #30), location 14 can be used to restrict certain codes from activating certain outputs. Location 14 contains 10 segments. Segment 1 corresponds to user 61; Segment 10 corresponds to user 70.
  • Page 16: Programming Worksheets

    PROGRAMMING WORKSHEETS XIII. (Defaults are printed in bold italics text.) At Default: Output A = AUX POWER Output B = AUX POWER Output C = SMOKE POWER PAGE DESCRIPTION DEFAULT DATA OUTPUT A EVENT & TIME 0 10 OUTPUT A SPECIAL FEATURES Segment 1 Segment 2 1 = "On"...
  • Page 17 PAGE DESCRIPTION Codes 1-10 Output Enable (Circle the numbers to program) User Output #A Output #B Output #C Codes 11-20 Output Enable (Circle the numbers to program) User Output #A Output #B Output #C Codes 21-30 Output Enable (Circle the numbers to program) User Output #A Output #B...
  • Page 18 PAGE DEFAULT DATA DESCRIPTION A/C Delay (in minutes) Dynamic Battery Test (in minutes) Device Options (Circle the numbers to program) 1=On for AC report always sent; Off follows control 5=Reserved 6=Reserved 2=On enables periodic battery test 7=Reserved 3=On enables low battery reporting 8=Reserved 4=On enables siren tamper/trouble reporting NX-320E Power Supply...
  • Page 19 NOTES NX-320E Power Supply...
  • Page 20: Specifications

    32 to 120 degrees F SHIPPING WEIGHT 8 lbs. 1420 NORTH MAIN STREET GLADEWATER, TEXAS 75647 Main 800-727-2339 Technical Support 800-727-2339 Outside the US 903-845-6941 Tech Support Fax 903-845-8409 Main Fax 903-845-6811 Sales & Literature 800-547-2556 Web: www.caddx.com www.ge-interlogix.com NX320EIE03 REV E (Feb 2003)