GE NX-591E Installation And Startup Manual

Cellemetry module

Advertisement

Quick Links

NetworX Series
NX-591E Cellemetry Module
Installation and Startup

Advertisement

Table of Contents
loading

Summary of Contents for GE NX-591E

  • Page 1 NetworX Series ™ NX-591E Cellemetry Module Installation and Startup...
  • Page 2: Table Of Contents

    Special Events To Report To Central Station........15 Location 10 Events To Report To Email ..............15 Location 11 Special Events To Report To Email............16 Location 12 Events To Report To Pager ..............16 Location 13 Special Events To Report To Pager ...........17 XII. PROGRAMMING WORKSHEETS................18 XIII. SPECIFICATIONS.......................24 NX-591E...
  • Page 3: General Description

    The NX-591E is a microprocessor-controlled Cellemetry interface used to connect the NetworX series of control panels to AMPS cellular network for event reporting. The NX-591E can be used for primary, backup, or additional reporting when used in conjunction with the panel communicator or other optional reporting modules.
  • Page 4: Enclosure Information

    5dB “Mag Mount”. MODULE ADDRESS The cellemetry module has a fixed address of 76. When programming the module, enter the Program Mode and select the device address as 76. (See "PROGRAMMING THE MODULE", page 8.) NX-591E...
  • Page 5: Enrolling The Module

    Connect to the KP POS terminal of the panel. Refer to “Specifications” in this manual for power consumption. Connect to the KP COM terminal of the panel. DATA Connect to the KP DATA terminal of the panel. TAMPER Normally closed NX-591E...
  • Page 6: Viii. Understanding The Lights

    Data being received from cellemetry radio Data being sent to cellemetry radio Table VIII-2 POOR FAIR GOOD BEST -114 -107 -106 -104 LED Key -103 -101 -100 0 = OFF S = SLOW F = FAST 1 = ON higher NX-591E...
  • Page 7: Connection Diagram

    CONNECTION DIAGRAM NX-591E...
  • Page 8: Programming The Module

    To Enter a Location: The Armed LED will flash. If the location is valid, [location] the "Armed" LED will extinguish, the "Ready" LED will illuminate, and the zone LED’s will show the data for the first segment of this location. NX-591E...
  • Page 9: Exiting The Program Mode

    (Do not enter data.) The next segment is displayed. Each time pressed, the data of the next segment will be displayed for review. Shortcuts: Previous location. Same location. Next sequential location. Exiting the Program Mode: Exits this programming level. EXIT NX-591E...
  • Page 10: Using The Lcd Keypad

    USING THE LCD KEYPAD All steps required for programming are the same as the aforementioned LED keypad. The LCD keypad display will prompt you for the data required. While in the programming mode, and not in a location, the number in parenthesis is the location you were previously changing. For example, if the display reads, "Enter location, then # (5)", it is reminding you that location 5 was the last location you programmed.
  • Page 11: Programming Instructions

    Segment 2 programs for Host Acknowledgement requirements. Factory default for all options is OFF. Option Description Central Station messages Enabled Disabled Email messages Enabled Disabled Pager messages Enabled Disabled Periodic test signals Enabled Disabled Reserved Segments 3 and 4 are reserved for future use. NX-591E...
  • Page 12: Loc 2 -7 When Phone Fault Is Detected

    Loc 2 –7 When Phone Fault Is Detected Location 2 Events To Report To Central Station (Phone fault detected) 16 segments of Feature Selection Data Reporting must be enabled in the control panel for this location to function properly. This location selects the partition(s) to include when reporting to the Central Station. To exclude any partition from reporting, simply turn off the LED corresponding to that particular partition.
  • Page 13: Location 4 Events To Report To Email

    LED corresponding to that particular partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 –16. Factory default is all partitions OFF. NX-591E...
  • Page 14: Location 7 Special Events To Report To

    SEGMENT DESCRIPTION SEGMENT DESCRIPTION Alarms Tampers Open/Close Short Circuit & Ground Fault Bypass Sensor Lost Zone Trouble Sensor Low Battery Power Trouble (AC Failure or Expander Trouble Low Battery) Siren & Telephone Fault Failure To Communicate Test Reports Zone Activity Monitor Program, Download &...
  • Page 15: Loc 8 -13 When Phone Line Is Good

    To exclude any partition from reporting, simply turn off the LED corresponding to that particular partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 –16. Factory default is all partitions OFF NX-591E...
  • Page 16: Location 11 Special Events To Report To Email

    SEGMENT DESCRIPTION SEGMENT DESCRIPTION Alarms Tampers Open/Close Short Circuit & Ground Fault Bypass Sensor Lost Zone Trouble Sensor Low Battery Power Trouble (AC Failure or Expander Trouble Low Battery) Siren & Telephone Fault Failure To Communicate Test Reports Zone Activity Monitor Program, Download &...
  • Page 17: Location 13 Special Events To Report To

    Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 – 8. Factory default is all partitions OFF. SEGMENT DESCRIPTION Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved SYSTEM NOTES NX-591E...
  • Page 18: Programming Worksheets

    XII. PROGRAMMING WORKSHEETS DEFAULTS ARE SHOWN IN BOLD ITALICS LOC PG SEG DESCRIPTION DEFAULT DATA SYSTEM ID (all 0’s = AutoSID) _ _ _ _ _ 0-0-0-0-0 FEATURE SELECTION 1 = SIA Format (Off = Contact ID) 2 = Daily Test Signal (Off = Weekly) 3 = System Preference (Off = No preference) 4 = “B”...
  • Page 19 Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble Fail to Communicate Zone Activity Monitor Reserved REPORTING SPECIAL EVENTS TO EMAIL (Phone line fault detected) Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved NX-591E...
  • Page 20 LOC PG SEG DESCRIPTION PARTITION REPORTING EVENTS TO PAGER (Phone line fault detected) Alarms Open / Close Bypass Zone Trouble Power Trouble (AC Fail or Low Battery) Siren & Telephone Fault Test Reports Program, Download & Log Full Tampers Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble...
  • Page 21 Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble Fail to Communicate Zone Activity Monitor Reserved REPORTING SPECIAL EVENTS TO EMAIL (Phone line is good) Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved NX-591E...
  • Page 22 LOC PG SEG DESCRIPTION PARTITION REPORTING EVENTS TO PAGER (Phone line is good) Alarms Open / Close Bypass Zone Trouble Power Trouble (AC Fail or Low Battery) Siren & Telephone Fault Test Reports Program, Download & Log Full Tampers Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble...
  • Page 23 ORDERING INFORMATION PART # PART # DESCRIPTION DESCRIPTION NX-591E Cellemetry Module NX-108E 8 Zone LED Horizontal Keypad NX-591E- Magnetic Mount Antenna NX-116E 16 Zone LED Horizontal MAG MOUNT Keypad P-0005 2dB “Rubber Ducky” NX-124E 24 Zone LED Horizontal Antenna Keypad...
  • Page 24: Xiii. Specifications

    XIII. SPECIFICATIONS OPERATING POWER 12VDC Supplied from NX Control Panel or NX-320E Power Supply POWER CONSUMPTION Standby w/ Service LEDs disabled 70mA Max Standby w/ Service LEDs enabled 90mA Max Transmission Burst (<1 second) 1300mA Max OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 2.40"...