Special Events To Report To Central Station........15 Location 10 Events To Report To Email ..............15 Location 11 Special Events To Report To Email............16 Location 12 Events To Report To Pager ..............16 Location 13 Special Events To Report To Pager ...........17 XII. PROGRAMMING WORKSHEETS................18 XIII. SPECIFICATIONS.......................24 NX-591E...
The NX-591E is a microprocessor-controlled Cellemetry interface used to connect the NetworX series of control panels to AMPS cellular network for event reporting. The NX-591E can be used for primary, backup, or additional reporting when used in conjunction with the panel communicator or other optional reporting modules.
5dB “Mag Mount”. MODULE ADDRESS The cellemetry module has a fixed address of 76. When programming the module, enter the Program Mode and select the device address as 76. (See "PROGRAMMING THE MODULE", page 8.) NX-591E...
Connect to the KP POS terminal of the panel. Refer to “Specifications” in this manual for power consumption. Connect to the KP COM terminal of the panel. DATA Connect to the KP DATA terminal of the panel. TAMPER Normally closed NX-591E...
Data being received from cellemetry radio Data being sent to cellemetry radio Table VIII-2 POOR FAIR GOOD BEST -114 -107 -106 -104 LED Key -103 -101 -100 0 = OFF S = SLOW F = FAST 1 = ON higher NX-591E...
To Enter a Location: The Armed LED will flash. If the location is valid, [location] the "Armed" LED will extinguish, the "Ready" LED will illuminate, and the zone LED’s will show the data for the first segment of this location. NX-591E...
(Do not enter data.) The next segment is displayed. Each time pressed, the data of the next segment will be displayed for review. Shortcuts: Previous location. Same location. Next sequential location. Exiting the Program Mode: Exits this programming level. EXIT NX-591E...
USING THE LCD KEYPAD All steps required for programming are the same as the aforementioned LED keypad. The LCD keypad display will prompt you for the data required. While in the programming mode, and not in a location, the number in parenthesis is the location you were previously changing. For example, if the display reads, "Enter location, then # (5)", it is reminding you that location 5 was the last location you programmed.
Segment 2 programs for Host Acknowledgement requirements. Factory default for all options is OFF. Option Description Central Station messages Enabled Disabled Email messages Enabled Disabled Pager messages Enabled Disabled Periodic test signals Enabled Disabled Reserved Segments 3 and 4 are reserved for future use. NX-591E...
Loc 2 –7 When Phone Fault Is Detected Location 2 Events To Report To Central Station (Phone fault detected) 16 segments of Feature Selection Data Reporting must be enabled in the control panel for this location to function properly. This location selects the partition(s) to include when reporting to the Central Station. To exclude any partition from reporting, simply turn off the LED corresponding to that particular partition.
LED corresponding to that particular partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 –16. Factory default is all partitions OFF. NX-591E...
To exclude any partition from reporting, simply turn off the LED corresponding to that particular partition. Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 –16. Factory default is all partitions OFF NX-591E...
Using Table XI-1 on page 12, enter the corresponding number of the partition(s) to include for each type of report found in Segments 1 – 8. Factory default is all partitions OFF. SEGMENT DESCRIPTION Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved SYSTEM NOTES NX-591E...
XII. PROGRAMMING WORKSHEETS DEFAULTS ARE SHOWN IN BOLD ITALICS LOC PG SEG DESCRIPTION DEFAULT DATA SYSTEM ID (all 0’s = AutoSID) _ _ _ _ _ 0-0-0-0-0 FEATURE SELECTION 1 = SIA Format (Off = Contact ID) 2 = Daily Test Signal (Off = Weekly) 3 = System Preference (Off = No preference) 4 = “B”...
Page 19
Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble Fail to Communicate Zone Activity Monitor Reserved REPORTING SPECIAL EVENTS TO EMAIL (Phone line fault detected) Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved NX-591E...
Page 20
LOC PG SEG DESCRIPTION PARTITION REPORTING EVENTS TO PAGER (Phone line fault detected) Alarms Open / Close Bypass Zone Trouble Power Trouble (AC Fail or Low Battery) Siren & Telephone Fault Test Reports Program, Download & Log Full Tampers Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble...
Page 21
Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble Fail to Communicate Zone Activity Monitor Reserved REPORTING SPECIAL EVENTS TO EMAIL (Phone line is good) Alarm Restores Telephone Fault Start Download Fail to Communicate, Data Lost Reserved NX-591E...
Page 22
LOC PG SEG DESCRIPTION PARTITION REPORTING EVENTS TO PAGER (Phone line is good) Alarms Open / Close Bypass Zone Trouble Power Trouble (AC Fail or Low Battery) Siren & Telephone Fault Test Reports Program, Download & Log Full Tampers Short Circuit & Ground Fault Sensor Lost Sensor Low Battery Expander Trouble...
Page 23
ORDERING INFORMATION PART # PART # DESCRIPTION DESCRIPTION NX-591E Cellemetry Module NX-108E 8 Zone LED Horizontal Keypad NX-591E- Magnetic Mount Antenna NX-116E 16 Zone LED Horizontal MAG MOUNT Keypad P-0005 2dB “Rubber Ducky” NX-124E 24 Zone LED Horizontal Antenna Keypad...
XIII. SPECIFICATIONS OPERATING POWER 12VDC Supplied from NX Control Panel or NX-320E Power Supply POWER CONSUMPTION Standby w/ Service LEDs disabled 70mA Max Standby w/ Service LEDs enabled 90mA Max Transmission Burst (<1 second) 1300mA Max OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 2.40"...