When neutral wire of inverter is not connected to grid, "Delta Grid" should be selected in grid
type(IT) setting page.
Transformer

3.2 Inverter Overview

3.2.1 GEP series inverter illustration
GEP12~20-L-10
GEP25~36-10
1
2
3
4
5
ON
L1 L2 L3 N PE
MPPT1
+
MPPT2
+
MPPT3
+
PV1
PV2
PV3
PV4
PV5
PV6
OFF
RS-485
WITH LCD
GEP30~35-L-10
GEP50~60-10
1
2
3
4
5
L1
L2
L3
N
PE
ON
RS-485
OFF
05
IT
L1
L2
L3
PE
Inverter
6
9
7
8
WITHOUT LCD
6
7
8
WITH LCD
WITHOUT LCD
Image shown here is for reference only, actual product you receive may differ.
Item
1
2
3
4
5
6
7
8
9
3.2.2 DC Switch
The DC switch is designed such that the DC input can be disconnected safely.
The inverter works automatically when the input and output meet the requirements. Rotating the
DC switch to "OFF" position will immediately cut off the flow of DC current.Rotate the DC switch to
"ON" position before starting the inverter.

3.3 Technical Description

3.3.1 Principle Description
PV string voltage is transmitted to DC BUS via BOOST circuit.
The GEP series is equipped with Three or Six MPPTs for Six, Tweleve DC inputs to ensure that
the maximum power is utilized even in different PV installation condition.
DC/AC converter circuit convert DC power into AC power, which can be fed into the utility.
Protective circuit are designed to protect the inverter safety and human safety.
DC switch is integrated to allow for a safe disconnection from the DC input. The inverter provides
standard interface RS485, WIFI for communication. Inverters also provide running recode data
display, parameter configuration via LCD panel.For the main block diagram please refer to chapter
7.2.
3.3.2 Function Description
9
Inverter functions can be grouped as following.
1. Conversion function
Inverter converts direct current power into alternating current power, which conforms to the grid
requirement of its installation country.
Name
Description
During normal operation it is in "on" state, it can shut down
DC Switch (optional)
the inverter after it is disconnected from the grid by the AC breaker.
PV Input Port
For PV string connection
WiFi
WiFi For connection
RS485&DRED&USB Communication Port
For RS485 And DRED And USB Communication
AC output port
For AC cable connection
LED indicator light
Display the state of the inverter
Inverter operation data viewing and parameter configuration.
LCD display screen
Buttons
For configuration and viewing parameters.
Air Outlet
Exit of hot air during the inverter operation.