Download Print this page
Honeywell Wireless Network Master ETH/WIFI T2 Manual

Honeywell Wireless Network Master ETH/WIFI T2 Manual

Advertisement

Quick Links

Dimensional drawings:
120mm
The 138091 Wireless Network Master ETH/WiFi T2 is a master device (Gateway) with
Ethernet & Wi-Fi connectivity, for TELA2 Wireless Lighting system.
The 138091 is capable of monitoring up to 250 wireless devices (consisted of emergency
luminaires, extenders, I/O units, other), forming a wireless network.
The available connection methods to the local network are:
Ethernet (wired)
Ÿ
Wi-Fi - WPA2/PSK
Ÿ
Wi-Fi - WPS
Ÿ
The device supports both Dynamic (DHCP) and Static IPv4 addressing options. The
communication protocol is TCP with TLS/SSL security layer.
Installation:
Use the mounting holes to install the device to a wall surface. Avoid metallic surfaces or glass.
Use the spirit level (bubble) for horizontal alignment.
The 138091 must be supplied with a permanent 220-240V AC/50-60Hz power supply
through a circuit breaker equivalent to the total load of the emergency lighting equipment.
The device does not implement backup power supply in mains interruption; therefore, if the
monitoring system is required to be active during mains interruption (emergency), the device
must be supplied via a UPS power line.
If Ethernet connectivity is going to be used, the device must be placed close to an Ethernet
network source (socket/switch/router).
If Wi-Fi connectivity is going to be used, the device must be placed within range of a present
Wi-Fi network. Use a laptop or a smartphone to ensure signal level before installing.
The 138091 must be placed in a central point of the entire Wireless Lighting installation area
in order to achieve multiple available routes for the data transmitted (star connection). The
wireless network is "mesh" type, meaning that each wireless device is also a repeater. The
recommended number of wireless devices directly connected into the Gateway is 5 to 10.
Direct connection is achieved when a wireless device is located within Gateway wireless range
(20 to 25 meters – building interior).
Honeywell Life Safety AS, Postboks 263, 1372 Asker
Wireless
Network Master ETH/WiFi T2
104mm
http://www.hls-nordic.com
GB

Advertisement

loading

Summary of Contents for Honeywell Wireless Network Master ETH/WIFI T2

  • Page 1 Dimensional drawings: 104mm 120mm The 138091 Wireless Network Master ETH/WiFi T2 is a master device (Gateway) with Ethernet & Wi-Fi connectivity, for TELA2 Wireless Lighting system. The 138091 is capable of monitoring up to 250 wireless devices (consisted of emergency luminaires, extenders, I/O units, other), forming a wireless network.
  • Page 2 “BT3” button and “LD7” LED position Use your Wi-Fi device (laptop, smartphone) in order to connect to the Wi-Fi Access Point with the SSID (name): “WIRELESS_LIGHTING_GATEWAY” Use the following password when asked: “WIRELESSGW” Honeywell Life Safety AS, Postboks 263, 1372 Asker http://www.hls-nordic.com...
  • Page 3 2 – For Wi-Fi (WPA2/PSK) connectivity: In order to connect the 138091 Wireless Network Master ETH/WiFi T2 with the local network, using Wi-Fi connectivity, a Wi-Fi network with 802.11 b/g/n protocols and WPA2/PSK security must be active and within range. The Gateway will join the Wi-Fi network as a client.
  • Page 4 At the end of their useful life the packaging and product should be disposed of via a suitable recycling centre. Do not dispose of with your normal household waste. Do not burn. Honeywell Life Safety AS, Postboks 263, 1372 Asker http://www.hls-nordic.com...

This manual is also suitable for:

138091