12.2

Operating and Error Display

There are four LEDs as on the top of the front panel to display the device conditions
and errors of the connected control cabinet PC. Take one of the following measures if
one of the succeeding LEDs displays an error or a note.
LED
Display
LED green
LED off
Vin
LED yellow
LED flashes
HDD
yellow
LED off
LED flashes
red
TEMP
LED red
LED off
LED red
UPS
Fig.12-1: LEDs for operating and error display on the connector panel
If the panel PC is shut down under Windows and the 24 V input voltage is
switched off, the input voltage can only be switched on again when the
Vin-LED is off.
30/43
12
14
Meaning
Normal mode
No supply voltage DC 24 V
Hard disk access
Warning: SMART analysis
identifies errors
Normal mode
Fan does not rotate or rotates
too slowly
Overtemperature
Normal mode
The panel PC is currently run‐
ning in the UPS operating
mode. I.e. no supply voltage is
provided at the UPS!
DOK-SUPPL*-VSP*XX.3***-IT01-EN-P
Rexroth IndraControl VSP xx.3 Panel PC
Five PCI and one PCIe slot for exten‐
sion cards
Depending on the device variant Ma‐
chine function keys (M-keys) R1 to R8
(assignment see project planning
manual)
Measure
-
Check supply voltage
-
Exchange hard disk
-
Check fan in device!
Reduce surrounding air tem‐
perature!
-
Restore power supply and ini‐
tiate controlled restart of the
panel PC!