Bosch rexroth PR30 Operating Instructions Manual

Control cabinet pc and panel pc
Table of Contents

Advertisement

Quick Links

PR30 and VR30
Control Cabinet PC and Panel PC
Operating Instructions
R911384706
Edition 01

Advertisement

Table of Contents
loading

Summary of Contents for Bosch rexroth PR30

  • Page 1 PR30 and VR30 Control Cabinet PC and Panel PC Operating Instructions Edition 01 R911384706...
  • Page 2 Refer to tab. 1-1 "Change Record" on page 1 Change Record Copyright © Bosch Rexroth AG 2019 All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
  • Page 3: Table Of Contents

    Connecting cables of the display port........... 7 Wear parts..................... 5.6.1 CMOS battery..................Ambient conditions................8 Technical data..................9 PC box....................Panel PC....................Optical characteristic values..............10 7.3.1 TFT....................... 10 7.3.2 Input system or multi-touch front............R911384706_Edition 01 Bosch Rexroth AG...
  • Page 4 10.9.3 Connecting the control cabinet PC to the 24 V voltage supply.... 31 10.9.4 Total connection diagram - Power supply unit, UPS and control cabi- net PC....................32 Commissioning..................11.1 IT security.................... Device description................12.1 Display....................Bosch Rexroth AG R911384706_Edition 01...
  • Page 5 14.2 Scheduled maintenance tasks............. Ordering information................15.1 Accessories and spare parts..............36 15.2 Type code..................... 37 Disposal....................16.1 Return....................40 16.2 Packaging..................... 41 16.3 Recycling....................41 16.4 Batteries and accumulators..............Service and support................Index....................43 R911384706_Edition 01 Bosch Rexroth AG...
  • Page 6 PR30 and VR30 Control Cabinet PC and Panel PC Bosch Rexroth AG R911384706_Edition 01...
  • Page 7: About This Documentation

    Fig. 1-1: Assigning the present documentation to the target groups, product phases and ac- tivities of the target group 1.2 Purpose This document instructs the technical staff of the machine manufacturer on how to perform the mechanical and electrical installation safely and on how to commission the device. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 8: Scope

    Customer requests, comments or suggestions for improvement are of great importance to us. Please email your feedback on the documentations to Feedback.Documentation@boschrexroth.de. Directly insert comments in the electronic PDF document and send the PDF file to Bosch Rexroth. 2 Product identification and scope of delivery 2.1 Product identification...
  • Page 9: Scope Of Delivery

    PR30 and VR30 Control Cabinet PC and 3/45 Panel PC Using safety instructions Description Example Company address Bosch Rexroth AG, 97816 Lohr, Germany CE conformity marking Rexroth barcode Test marking I-V-C-B-T-V Voltage specification In 24 V DC Current specification In 4.2 A Ambient temperature T(amb) 0-55 °C...
  • Page 10: Explaining Signal Words And Safety Alert Symbol

    NOTICE In case of non-compliance with this safety instruction, material damage can occur. 3.3 Symbols used Pointers are displayed as follows: This is a note. Tips are displayed as follows: This is a tip. Bosch Rexroth AG R911384706_Edition 01...
  • Page 11: Explaining The Signal Alert Symbol On The Device

    ● Wood processing machines ● The devices may only be operated under the mounting and installation conditions, the position and the ambient conditions (temperature, degree of protection, humidity, EMC etc.) specified in the related documentation. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 12: Spare Parts, Accessories And Wear Parts

    RKB0008/030,0 (*******-*******-*******) R911171381 Length: 30 m RKB0008/035,0 (*******-*******-*******) R911171369 Length: 35 m RKB0008/040,0 (*******-*******-*******) R911171382 Length: 40 m RKB0008/050,0 (*******-*******-*******) R911171383 Length: 50 m RKB0008/055,0 (*******-*******-*******) R911173779 Length: 55 m RKB0008/060,0 (*******-*******-*******) R911173780 Length: 60 m Bosch Rexroth AG R911384706_Edition 01...
  • Page 13: Usb Connecting Cables (Usb 2.0)

    Ordering code Part number Description RKB0063/003,0 (*******-*******-*******) R911391713 Connecting cable display port, length 3 m RKB0063/005,0 (*******-*******-*******) R911391714 Connecting cable display port, length 5 m 5.6 Wear parts Wear parts are not subject to any warranty. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 14: Cmos Battery

    DIN EN 55022). NOTICE Defective product due to gases jeopardizing functions Due to the risk of corrosion, avoid sulphurous gases (e.g. sulphur dioxide (SO and hydrogen suphide (H S)). The product is not resistant against these gases. Bosch Rexroth AG R911384706_Edition 01...
  • Page 15: Technical Data

    1 × CDI+tx operating display connection at a large distance TPM 2.0 (onboard) chip: INFINEON_SLB 9665TT2.0 RTC battery Button cell BR2032 Mounting Front uprights mounting Input voltage 24 V DC +25 %, -20 % with IEC 61131-2 R911384706_Edition 01 Bosch Rexroth AG...
  • Page 16: Panel Pc

    Standard Description EN 60204 -1 Safety of machinery – Electrical equipment of machines EN 61000-6-4 Generic standards – Emission standard (industrial environments) EN 61000-6-2 Generic standards – Noise immunity (industrial environments) EN 60068-2-6 Vibration test Bosch Rexroth AG R911384706_Edition 01...
  • Page 17: Fcc

    CE marking applies only to the device upon delivery. After modifying the device, verify the CE conformity. 8.4 UL/CSA certified The devices are certified acc. to UL 61010-2-201 (Industrial Control Equipment) and ● CSA22.2 No. 61010-2-201 (CSA) ● R911384706_Edition 01 Bosch Rexroth AG...
  • Page 18: Interfaces

    UL and CSA marking applies only to the device upon delivery. After modifying the device, verify the UL and the CSA conformity. 9 Interfaces Fig. 9-1: Interfaces PR30 without CDI+ interface XCDI+tx Fig. 9-2: Interfaces PR30 with CDI+ interface Bosch Rexroth AG R911384706_Edition 01...
  • Page 19: Overview

    D-SUB plug, 9-pin D-SUB socket, 9-pin XETH1, XETH2, XETH3 Ethernet interfaces RJ45 socket, 8-pin RJ45 plug 10/100/1000 Base-T (twisted pair, 8-wire) XUSB1, XUSB2 USB3.0 interfaces USB socket, USB plug, 8-pin, type A 8-pin, type A R911384706_Edition 01 Bosch Rexroth AG...
  • Page 20: Pc Voltage Supply X1S1

    The 24 V DC voltage supply for the control cabinet PC is connected via the "X1S1" connection. 1 2 3 Fig. 9-4: Interface for 24 V voltage supply Function +24 V supply voltage ① 0 V supply voltage ② Functional earth ③ Tab. 9-2: Bosch Rexroth AG R911384706_Edition 01...
  • Page 21: Usb Interfaces Xusb1 To Xusb4

    DVI or HDMI monitor. No image is shown if a passive converter is used. 9.7 Long distance XCDI+tx At the long-distance (XCDI+tx), A cable length of up to 100 m can be used to interconnect remote operating displays to the individual devices. Fig. 9-6: XCDI+ connection R911384706_Edition 01 Bosch Rexroth AG...
  • Page 22: Mounting, Demounting And Electric Installation

    10.1 Dimensions of the BC box The control cabinet PC can be mounted in front upright mounting using mounting holes. For the corresponding dimension, refer to the following figures: Fasten the devices using M6 screws. Bosch Rexroth AG R911384706_Edition 01...
  • Page 23 PR30 and VR30 Control Cabinet PC and 17/45 Panel PC Mounting, demounting and electric installation ① Optional CDI+ box Fig. 10-1: Mounting dimensions for device, front upright mounting R911384706_Edition 01 Bosch Rexroth AG...
  • Page 24 18/45 PR30 and VR30 Control Cabinet PC and Panel PC Mounting, demounting and electric installation 186.15 196.75 Fig. 10-2: Housing dimensions, left side view Bosch Rexroth AG R911384706_Edition 01...
  • Page 25 PR30 and VR30 Control Cabinet PC and 19/45 Panel PC Mounting, demounting and electric installation 106.1 86.4 ① Optional CDI+ box Fig. 10-3: Housing dimensions, top view R911384706_Edition 01 Bosch Rexroth AG...
  • Page 26: Housing Dimensions Of The Panel Pc, Front View Vr3015

    Fig. 10-4: Front view of the Panel PC ① ② ③ ④ ⑤ Display size Device width Device height Display width Display height Frame width 15" Tab. 10-2: Housing dimensions of the VR3015 in millimeters Bosch Rexroth AG R911384706_Edition 01...
  • Page 27: Housing Dimensions Of The Panel Pc Vr3015

    PR30 and VR30 Control Cabinet PC and 21/45 Panel PC Mounting, demounting and electric installation 10.3 Housing dimensions of the panel PC VR3015 Fig. 10-5: Housing dimensions of the device VR3015, left side view R911384706_Edition 01 Bosch Rexroth AG...
  • Page 28: Installation Notes

    CDI connection can be disturbed. Keep the maximum distance possible from interference sources. 10.5 Installing components 10.5.1 Replacing the CMOS battery To replace the CMOS battery BR2032, open the cover on the top of the housing. Bosch Rexroth AG R911384706_Edition 01...
  • Page 29: Device Mounting Of The Panel Pc

    Panel PC Mounting, demounting and electric installation Fig. 10-7: Replacing the CMOS battery Ensure the correct polarity when inserting the new CSMO battery! 10.6 Device mounting of the panel PC Install the panel PC as follows: R911384706_Edition 01 Bosch Rexroth AG...
  • Page 30 Fig. 10-8: Mounting screws at the bottom of the display 3. Install the panel PC into the mounting cut-out. The detents fasten the panel PC in the opening. Bosch Rexroth AG R911384706_Edition 01...
  • Page 31 PR30 and VR30 Control Cabinet PC and 25/45 Panel PC Mounting, demounting and electric installation ① Detents Fig. 10-9: Detents on the upper side of the display R911384706_Edition 01 Bosch Rexroth AG...
  • Page 32 Mounting, demounting and electric installation Fig. 10-10: Display in the mounting cut-out 4. Insert each fastening element into an opening and pull the fastening element back until it is in the rear part of the opening: Bosch Rexroth AG R911384706_Edition 01...
  • Page 33 Fig. 10-11: Inserting fastening element into the opening 5. Tighten the cross-slotted screws. Fig. 10-12: Panel PC holders To ensure a high degree of moisture resistance, use a mounting torque of 0.5 Nm (4.5 lb-in). R911384706_Edition 01 Bosch Rexroth AG...
  • Page 34: Mounting Cut-Out

    Consider the weight of the display and of the PC. Especially if ● there is a strong vibration. Reinforce the front plate with slates at the internal side close of the mounting cut-out if required. Bosch Rexroth AG R911384706_Edition 01...
  • Page 35: Demounting

    Fig. 10-14: Wiring the control cabinet PC to the operating display Connection 1. Connect the functional earth. 2. Connect the XCDI+tx interface at the control cabinet PC to the XCDi+rx interface at the respective operating display using a CDI+ cable. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 36: Connecting The Control Cabinet Pc To Multiple Operating Displays

    “Clone” mode. The advanced mode can only be used if a second display is connected to the display port. The touch function is always active on all operating displays. Entries can not be blocked at individual operating displays. Bosch Rexroth AG R911384706_Edition 01...
  • Page 37: Connecting The Control Cabinet Pc To The 24 V Voltage Supply

    +rx" is sufficient for the last location. 10.9.3 Connecting the control cabinet PC to the 24 V voltage supply 1. Connect the "X1S1" interface for the 24 V voltage supply to the industrial power supply unit. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 38: Total Connection Diagram - Power Supply Unit, Ups And Control Cabinet Pc

    IT security. Bosch Rexroth products are part of this integral concept. Bosch Rexroth product characteristics have to be taken into consideration in an integral IT security concept. The relevant characteristics are documented in the IT security guideline (R911342562).
  • Page 39: Device Description

    ⑪ Power and Reset button USB Interfaces (USB3.0) ⑤ ⑫ Status LED Display port interfaces ⑥ ⑭ Serial interfaces Bulk memory ⑦ ⑮ Voltage supply mPCIe interface module ⑧ Functional earth Fig. 12-2: PC box R911384706_Edition 01 Bosch Rexroth AG...
  • Page 40: Reset And Power Button

    Tab. 12-2: Status LEDs for operating and error display on the front panel 12.2.3 Operating and error display of the PC box ④. The status LED are located at the interfaces, refer to on page 0 Bosch Rexroth AG R911384706_Edition 01...
  • Page 41: Error Causes And Troubleshooting

    Connect the display port or CDI+ cables correctly ● If panels with a display port are used, use only Bosch ● Rexroth display cables to connect the panels, refer to chapter 5.5 "Connecting cables of the display port" on page Use only active DVI and HDMI display port adapters.
  • Page 42: Cleaning Notes

    Damaged parts must be replaced immediately. ● 15 Ordering information 15.1 Accessories and spare parts For ordering information on accessories and spare parts, refer to chapter 5 "Spare parts, accessories and wear parts" on page 6 Bosch Rexroth AG R911384706_Edition 01...
  • Page 43: Type Code

    Version 1 Reserve 16-21 None = NN NN NN NN NN NN Fig. 15-1: Type code for PR3 devices F03 (performance class) F07 (bulk memory) 1, A, B F03 (performance class) F08 (memory) 0, 1 R911384706_Edition 01 Bosch Rexroth AG...
  • Page 44 PR30 and VR30 Control Cabinet PC and Panel PC Ordering information F03 (performance class) F10 (mPCIe without interface) F03 (performance class) F11 (mPCIe with interface) 0, E F03 (performance class) F22 (material identifier) H, B Tab. 15-1: Dependency table Bosch Rexroth AG R911384706_Edition 01...
  • Page 45 16-21 None .......................= NN NN NN NN NN NN Fig. 15-2: Type code for VR3 devices F03 (performance classes) F04 (display size) F09 (design and display) 10, 15, 21 F03 (performance classes) F07 (bulk memory) R911384706_Edition 01 Bosch Rexroth AG...
  • Page 46: Disposal

    Furthermore, the products returned for disposal must not contain any undue foreign substances or external components. Send the products free of charge to the following address: Bosch Rexroth AG Bürgermeister-Dr.-Nebel-Straße 2 97816 Lohr am Main, Germany Bosch Rexroth AG R911384706_Edition 01...
  • Page 47: Packaging

    Additional information on service, repair (e.g. delivery addresses) and training can be found on our internet sites. Service worldwide Outside Germany, please contact your local service office first. For hotline numbers, refer to the sales office addresses on the internet. R911384706_Edition 01 Bosch Rexroth AG...
  • Page 48 Detailed description of malfunction and circumstances ● Type plate specifications of the affected products, in particular type codes ● and serial numbers Your contact data (phone and fax number as well as your e-mail address) ● Bosch Rexroth AG R911384706_Edition 01...
  • Page 49: Index

    Optical characteristic values..10 Dimensions....... 16, 20, 21 Ordering information....36 Display.......... 33 DisplayPort........15 Disposal........40 Panel PC Documentation Technical data......10 Change record......1 Panels PCs, device mounting..23 PC box.......... 33 Technical data......9 R911384706_Edition 01 Bosch Rexroth AG...
  • Page 50 Type code........37 UL/CSA certified......11 Uninterruptible power supply..6 UPS..........6 USB connecting cables....7 USB interfaces......15 Voltage supply....... 14 Warnings......... 3 Wear parts........6, 7 X1S1..........14 XCDI+tx......... 15 XDP..........15 XETH..........15 Bosch Rexroth AG R911384706_Edition 01...
  • Page 51 PR30 and VR30 Control Cabinet PC and 45/45 Panel PC Notes...
  • Page 52 Bosch Rexroth AG Electric Drives and Controls P.O. Box 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Phone +49 9352 18 0 Fax +49 9352 18 8400 www.boschrexroth.com/electrics *R911384706* R911384706 DOK-CONTRL -PR30VR30***-IT01-EN-P...

This manual is also suitable for:

Rexroth vr30

Table of Contents