ECOMAX
®
for indirect heating systems
▷ For an indirect heating system, the radi-
ant tube  SER, the segmented flame tubes
SICAFLEX
®
and the flue gas connector FLUP
are required, see page 16 (Accessories).
With ceramic radiant tube (SER-C)
FLUP
▷ The ceramic radiant tube (SER-C) must be cor-
rectly installed on the furnace before the burner
is installed, see www.docuthek.com → Thermal
Solutions → Products → 07 Industrial burners →
07b Self-recuperative and radiant tube burners
→ Radiant tube SER-C.
▷ Installation of the internal segmented flame tubes
, see www.docuthek.com → Ther-
SICAFLEX
®
mal Solutions → Products → 07 Industrial burn-
ers → 07b Self-recuperative and radiant tube
burners → Segmented flame tube SICAFLEX.
▷ Depending on the installation situation and ra-
diant tube diameter, a flue gas guide tube FGT
may be required, see page 16 (Accessories).
Installation of SER-C
CAUTION
Please observe the following to ensure that the
ceramic radiant tube SER-C is not damaged during
installation and operation:
▷ Open packaging carefully and without using
force.
▷ Insert into the furnace chamber without any
impacts or scratches to avoid damage and
breakage. Depending on the furnace atmos-
phere during operation, damage to the protec-
tive oxide layer on the surface of the radiant
tube can cause corrosion and thus reduce
the service life.
▷ We recommend that someone be inside the
furnace chamber to receive the radiant tube.
Note: for detailed information, refer to SER-C
operating instructions.
1
▷ Depending on the installation situation, a flue gas
2
guide tube FGT-set...SER-C may be required.
SER-C
Sicaflex
®
GB-4
With metallic radiant tube (SER-M)
FLUP
With metallic radiant tube (SER-M) and
eductor
EJEK
▷ The metallic radiant tube (SER-M) must be cor-
rectly installed on the furnace before the burner
is installed. Ensure there is a good seal between
the burner and SER-M.
▷ Installation of the internal segmented flame tubes
, see www.docuthek.com → Ther-
SICAFLEX
®
mal Solutions → Products → 07 Industrial burn-
ers → 07b Self-recuperative and radiant tube
burners → Segmented flame tube SICAFLEX.
▷ Depending on the installation situation, a flue gas
guide tube FGT set..D or an adapter flange may
be required (available on request as accessories).
CAUTION
Risk of breakage. Avoid impacts when inserting the
burner into the ceramic radiant tube and placing
on the stud bolts.
 Remove the transport safety device.
 Slide the FGT over the burner recuperator if it
has not yet been installed.
 Wrap a ceramic fibre blanket over the entire
length of the FGT. Compress the fibre blanket
to half its original thickness.
SER-M
Sicaflex
®
SER-M
Sicaflex
®