Technical Data; Logistics - Honeywell ECOMAX Operating Instructions Manual

Self-recuperative burner
Hide thumbs Also See for ECOMAX:
Table of Contents

Advertisement

Technical data

Heating: direct with eductor or indirect in radiant tube.
Control type: On/Off.
Adjusting range: 60% to 100%.
Flame velocity: approx. 130 to 170 m/s.
Flame control: direct ionization control (UV control
as an option).
Ignition: direct spark ignition.
Burner
Recuperator
Ceramic
ECOMAX
®
..C
(SiSiC)
ECOMAX
®
..M/
Cast steel
ECOMAX
®
..P
ECOMAX
®
..F
Metallic
*
We advise against using this in forging and heat-
ing furnaces in which raw material is heated.
Burner
Capacity [kW]
ECOMAX
®
0
25
ECOMAX
®
1
36
ECOMAX
®
2
60
ECOMAX
®
3
100
ECOMAX
®
4
180
ECOMAX
®
5
250
ECOMAX
®
6
500
*
Visible range for natural gas operation in the
open air, max. connection rating and air in-
dex 1.15.
If the burners are used at geodetic altitudes of over
500 m above MSL, the possible capacity will be
lower as a result of the reduced density of gas and air.
Guide value: 5% per 1000 m above MSL.
WARNING
Information pursuant to REACH Regulation No.
1907/2006, Article 33.
Insulation contains refractory ceramic fibres (RCF)/
aluminium silicate wool (ASW).
RCF/ASW are listed in the Candidate List of the
European REACH Regulation No. 1907/2006.
▷ Information on the safe handling of products
containing ceramic fibres can be found in the
safety data sheets.
▷ Safety data sheets are available on request.
Transport
Protect the unit from external forces (blows, shocks,
vibration). On receipt of the product, check that the
delivery is complete, see page  2 (Part designa-
tions). Transport the product in dry, clean conditions.
Report any transport damage immediately.
Storage
Max. flue gas
Store the product in a dry and clean place.
Storage temperature: see page 18 (Technical data).
temperature at
Storage time: 2 years before using for the first time. If
recuperator inlet
stored for longer than this, the overall service life will
1250°C*
be reduced by the corresponding amount of extra
storage time.
1150°C
Packaging
1050°C
The packaging material is to be disposed of in ac-
cordance with local regulations.
Disposal
Components are to be disposed of separately in
Flame length
accordance with local regulations.
[mm]*
300
300
400
450
800
800
1000
GB-18

Logistics

Advertisement

Table of Contents
loading

This manual is also suitable for:

03251385