Indicator LEDs
Normal
Charging (battery test not possible while charging)
Mains off, battery not connected or charger fault
Battery test (Duration: 1h,3h,8h)
Battery fault
Light source test (Duration: 3s)
Light source fault
Battery fault and light source fault
LED Status explanation
Off
On
The ExitLED PRO is a self-contained maintained/non-maintained luminaire with selftest function.
Selftest functions
Every 15 days the luminaire will perform an emergency operation test. This will turn on the light source for
approximately 3 seconds. The green LED will flash during this test sequence.
Every 6 months the luminaire will perform a battery condition test. The test will last for the chosen capacity. The light
source will be lit and the green LED will flash during this test sequence.
Note: When using DALI or Wireless communication, the frequencies and schedules for tests will instead be determined
by the connected PC software.
Manual test functions
Manual tests can only be performed if both mains and battery are connected.
By pressing the test button briefly (less than 5 seconds) an emergency operation
test is performed. The light source will be lit for approximately 3 seconds, the
green LED will flash during this test sequence.
By pressing the test button for between 5 and 10 seconds a battery condition test
is performed.
This test will last for the chosen capacity and can only be performed when the
battery is fully charged (steady green LED). The light source will be lit and the
green LED will flash during this test sequence.
Resetting errors
Push the test button for >10 seconds to delete all indicated errors. Then the luminaire enters regular operation mode.
Dimming
By pressing the test button continuously for 15 seconds, when luminaire is connected to mains, the luminosity will be
reduced to 10% of its total luminance. In emergency mode the light output will remain unchanged.
To restore the original settings, repeat the above procedure.
The dimming setting remains stored in the luminaire even when both mains and battery voltages are disconnected.