1
4
Screw
Wall Plug
Power
Cable
7
To mount the luminaire to the wall, with or wihout supplied spacers, the mounting holes must face towards
to the wall.
Step 1: Dismantle the luminaire by sliding the mounting part as shown in picture.
Step 2: Slide the plastic part with the terminals to the mounting part, until you hear click sound.
Step 3: Install the ground wire as shown in picture.
Step 4: Fasten the mounting part with the supplied mounting accessories. Drill a hole on a black grommet
and pass the mains cables through it.
Step 5: Connect the mains cables to terminal blocks: L for live wire, N for neutral and PE for ground. Power
supply cables cross section should be 0.8 - 3 mm . The C1 and C2 terminals are used for elBus
communication optional), DALI communication (optional), or voltage free contact (optional).
Tighten the cable tie around the cables.
Step 6: Slide the main body of the luminaire back to the mounting part.
Step 7: Fasten the screw on the side of the luminaire.
Step 8: Slide the aluminium protective covers to both sides of the luminaire, until you hear click sound.