Disarm - Honeywell IDENT KEY 3 Operating Manual

Operating unit with numerical keypad
Table of Contents

Advertisement

Available languages

Available languages

Operating Manual IK3 Operating Unit with Keypad
8.2

Disarm

The type of disarming is defined in the programming of the central control unit/EU. Optical and
acoustical acknowledgement is identical after an action has been performed.
1. Activate key (Quick)
2. Only IK data carrier
3. Only PIN
4. With IK data carrier and PIN
or
With PIN and IK data carrier
Acknowledgement:
Optical
Ready
(green)
Disarmed
(yellow)
Alarm
(red)
Acoustical
(signal)
Action
IK-D
0....9
IK-D
0....9
0....9
IK-D
Fulfilled with authorization
and positive drive
5 sec.
Dis-
Armed
armed
Lights up in case
of alarm
2 sec.
Positive acknowledge.
System is disarmed
Activate the "disarm" key, acknowledgement
follows
Activate the "disarm" key
Hold the IK data carrier in the reading range,
acknowledgement follows
Activate the "disarm" key
Enter PIN, acknowledgement follows
Activate the "disarm" key
Hold the IK data carrier in the reading range,
"Ready" flashes 1x
(if no authorization, negative acknowledgement)
Enter PIN, acknowledgement follows
Activate the "disarm" key
Enter PIN, "Ready" flashes 1x
(if no authorization, negative acknowledgement)
Hold IK data carrier in the reading range,
acknowledgement follows
No positive drive
5 sec.
Lights up in case
of alarm
Negative acknowledg.
System is
not
disarmed
No authorization
Negative acknowledg.
System is
not
disarmed
23