Methods of Installation
Explosion proof
Flexible conduit
(Not Supplied)
Fiber
Filler
Sealing Method
To install this product, please refer to Figure3 and do the following steps.
1. Make sure the threads of the supplied three M10X30mm stainless steel bolts and flat/spring washers are free
of dirt and debris.
2. Apply an amount of thread locking compound(not supplied) to the thread of the product and the thread of the
bolts.
3. Make sure the seal fittings(not supplied) and the threaded hole of this system are free of the dirt and particles.
4. Assemble nipple, the threaded hole of this system, seal fitting and flexible conduit(not supplied) to be fasten
firmly and then the cables must be passed through the seal fitting, Nipple and flexible conduit.
Plus, the sealing fitting, flexible conduit, Nipple should be acquired ATEX/IECEx Certification.
Note : Figure3 shows the product being installed on a surface with pedestal mount.
PT 3/4"-14 Nipple
PT 3/4"-14 Thread
PT 3/4 "-14
Seal Fitting
(Not Supplied)
Sealing
compou
Cables
nd
Install Product to Mounting surface
Figure3