Fuel conversion kits, these kits are for use at altitudes of 0 to 4500 feet

Advertisement

Available languages

Available languages

Quick Links

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
W175-0661, Propane to Natural Gas Includes:
1
STEP MOTOR / REGULATOR
2
#42 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
NATURAL GAS PILOT INJECTOR
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion,
or production of carbon monoxide may result causing property damage, personal injury, or
loss of life. The qualified service agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation of the converted appliance is
checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion, the gas supply must be
shut off prior to disconnecting the electrical power.
1. Remove the door, panels and media from the appliance. Refer to the
FINISHING section of your installation manual for instructions.
LOG VERSION:
2. Remove the 2 screws that secure the grate in place. Lift the grate up and
out. Remove the 4 screws securing the burner pan in place.
GLASS VERSION:
2b. Remove the 4 screws that secure the media tray in place. Lift the tray up
and out. Lift the burner support up and out. Remove the 4 screws holding
the burner pan in place.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KITS FOR MODEL
B35TL
These kits are for use at altitudes of 0 to 4500 feet.
W435-0010
W456-0042
W385-0075
W455-0068
W175-0660, Natural Gas to Propane Includes:
1
STEP MOTOR / REGULATOR
2
#54 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PROPANE PILOT INJECTOR
3. If the appliance is not installed and finished, remove the 2 screws
securing the access panel from the outside of the appliance. If the appliance
is installed and finished, remove the 8 screws that secure the access plate
to the firebox. NOTE: A new gasket may be required when re-installing
the access plate. Contact your local authorized dealer / distributor.
4. Using a deep socket wrench, remove the orifice. A back-up wrench
(not shown) must be used on the manifold to ensure that the tubing does
not twist or kink. Using pipe thread compound, replace with the orifice
supplied.
5. Adjust the air shutter using the outside air shutter adjustment lever (see
Venturi Adjustment table on next page for details).
6. To convert the main valve to the desired fuel, follow the leaflet for the
SIT step motor assembly that is included with this kit.
Continued on reverse
• 1(866)820-8686
W435-0010
W456-0054
W385-0075
W455-0068
W415-2227 / 01.25.18
• www.napoleon replaces.com

Advertisement

loading

Summary of Contents for Napoleon B35TL

  • Page 1 6. To convert the main valve to the desired fuel, follow the leaflet for the SIT step motor assembly that is included with this kit. Continued on reverse W415-2227 / 01.25.18 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 2 UPPER 3/8” (9.5mm) TO 1/2” (12.7mm) OF FLAME SENSOR LOG VERSION GLASS VERSION ÉLECTRODE VEILLEUSE 3/8” - 1/2” Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com (9,5mm - 12,7mm) LA SONDE DE FLAMME...
  • Page 3 6. Pour convertir la soupape principale au combustible désiré, suivez le feuillet pour l’assemblage du moteur pas-à-pas SIT qui est fourni avec cet ensemble. Suite au verso W415-2227 / 01.25.18 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfoyers.com...
  • Page 4 LA SONDE DE FLAMME LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) VERSION BÛCHES À 1/2” (12,7mm) VERSION VERRE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleonfoyers.com...