Table of Contents

Advertisement

Available languages

Available languages

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CONFORMS TO AMERICAN NATIONAL STANDARDS: ANSI Z21.50, CERTIFIED TO CANADIAN CSA 2.22 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
B30NTR / B30NTRE
NATURAL GAS MODEL
B30PTR / B30PTRE
PROPANE GAS MODEL
DANGER
!
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
BARRIER
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.28E
W415-1296 / A / 09.17.14
EN
FR
PG
65

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon B30NTR

  • Page 1: Safety Information

    BARRIER Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS NOTE: The camera icon indicates video tutorials are available as additional reference, visit http://www.napoleonfi replaces.com/category/product-support/support-centre/ INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATION SPECIAL VENT INSTALLATIONS 3.3.1...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW See the section “MINIMUM ENCLOSURE CLEARANCES” for drywall (or other combus- tible material). See the section “MINIMUM MANTEL CLEARANCES”. See the section “VENTING” and “INSTALLATION”. See the section “FRAMING”. See the section “NON-COMBUSTIBLE FINISHING”. Side Wall See the section “RATING PLATE INFORMATION”.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 12 3/4" 324mm 7" 34 1/2" 34 1/16" 178mm 876mm 866mm SAFETY BARRIER 24 3/16" 4" 614mm 102mm 6 11/16" 170mm 8 5/8" 136mm 14" 1 15/16" B30 ILLUSTRATED 355mm INLET 30" 50mm 762mm W415-1296 / A / 09.17.14...
  • Page 6: General Instructions

    GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”...
  • Page 7: General Information

    GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! RATES AND EFFICIENCIES Altitude (FT) 0-4,500 0-4500 Max. Input (BTU/HR) 15,000 15,000 Min. Inlet Gas Supply Pressure 4.5" (11mb) w.c. 11" (27mb) w.c. Max. Inlet Gas Supply 7"...
  • Page 8: Rating Plate Information

    T INFERIEUR 1" 1" 1" L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. MANTEL / MANTEAU 12" * REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST * MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION ON HORIZONTALE MAXIMALE: 2".
  • Page 9: Venting

    3.0 VENTING WARNING RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE. IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT (0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES.
  • Page 10: Venting Lengths And Components

    VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
  • Page 11: Typical Vent Installation

    TYPICAL VENT INSTALLATION 16" (406MM) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) MINIMUM 24" (610MM) MAXIMUM 8" (203MM) MINIMUM 42 1/16" (1068MM) MINIMUM PLUS 34 1/16" 34 1/16" RISE* (865MM) (865MM) TOP VENT W415-1296 / A / 09.17.14...
  • Page 12 16" (406MM) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) MINIMUM 20" (508MM) 24 3/16" 24 3/16" (614MM) (614MM) PLUS RISE REAR VENT * See "VENTING" section W415-1296 / A / 09.17.14...
  • Page 13: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum 12” (304.8mm) above grade. The maximum allowable vent length is 10’...
  • Page 14: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL (0.9m) (4.6m) INSTALLATIONS CANADA U.S.A. 12” (305mm) 12” (305mm) Clearance above grade, veranda porch, deck or balcony. 9” 12” (305mm) Clearance to windows or doors that open. Δ...
  • Page 15: Venting Application Flow Chart

    VENTING APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 16: Definitions

    DEFINITIONS For the following symbols used in the venting calculations and examples are: > - greater than > - equal to or greater than < - less than < - equal to or less than - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet - combined horizontal vent lengths in feet - offset factor: .03 (total degrees of offset - 90°*) in feet - combined vertical vent lengths in feet...
  • Page 17: Top Exit Horizontal Termination

    TOP EXIT HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H 40 (12.2) 39 (11.9) REQUIRED 30 (9.1) VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1)
  • Page 18 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the required horizontal run H (only one 90° elbow) 150 (3810) 147 (3733.8) REQUIRED VERTICAL 100 (2540) RISE IN INCHES (MILLIMETERS) V 57 (1447.8) 50 (1270) 10 (254) 8"...
  • Page 19: Top Exit Vertical Termination

    TOP EXIT VERTICAL TERMINATION ) < (V Simple venting configuration See graph to determine the required vertical rise V for the required (only two 90° elbows) horizontal run H 40 (12.2) 38.3 (11.7) 30 (9.1) REQUIRED VERTICAL RISE IN 20 (6.1) FEET (METERS) V 10 (3.1)
  • Page 20 ) > (V Simple venting configuration See graph to determine the required vertical rise V for the (only two 90° elbows) required horizontal run H 150(3810) 147 (3733.8 REQUIRED VERTICAL RISE IN 100 (2540) INCHES (MILLIMETERS)V (1676.4) 50 (1270) (304.8) 12.5 17.5 (0.8)
  • Page 21: Rear Exit Horizontal Termination

    3.10 REAR EXIT HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL RISE IN FEET 20 (6.1) (METERS)V 10 (3.1) 3 (0.9) (1.5) (3.1)
  • Page 22 ) > (V See graph to determine the required vertical rise V for the Simple venting configurations. required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL 10 (3.1) RISE IN FEET 3 (0.9) (METERS)V (1.5) (3.1) (4.6) (6.1) (7.6) (9.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H The shaded area within the lines represents acceptable...
  • Page 23: Rear Exit

    Example: = 1.5 FT (0.5m) = 5 FT (1.5m) = 1.5FT (0.5m)+ 5FT (1.5m) = 6.5 FT (2m) = 1 FT (0.3m) = 1 FT (0.3m) = 10.75 FT (3.3m) = 1FT (0.3m) + 1FT (0.3m) + 10.75FT (3.3m) = 12.75FT (3.9m) = .03 (four 90°...
  • Page 24: Installation

    4.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 25: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal VENT location, cut and frame a hole in the exterior wall as...
  • Page 26: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 27: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” (51mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 28: Appliance Vent Connection

    4.2.3 APPLIANCE VENT CONNECTION Install the inner exhaust fl ue collar to the appliance. Secure #8 X 1/2” with 3 screws. Seal the joint and screw holes using the high SELF temperature sealant Mill-Pac W573-0007 (not supplied). DRILLING SCREWS Install the outer fl ex pipe to the appliance. Attach and seal the 2”...
  • Page 29: Vertical Air Terminal Installation

    4.3.2 VERTICAL AIR TERMINAL INSTALLATION Move the appliance into position. INNER PIPE Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 30: Vertical Through Existing Chimney

    VERTICAL THROUGH EXISTING CHIMNEY WARNING RISK OF FIRE! CO-AXIAL TO CO-LINEAR VENTING CONFIGURATIONS MUST ONLY BE USED IN A NON- COMBUSTIBLE CHIMNEY OR ENCLOSURE. INSTALLATION IN A COMBUSTIBLE ENCLOSURE COULD RESULT IN A FIRE. This appliance is designed to be attached to a 3” (76.2mm) co-linear aluminum fl ex vent system running the full length of a masonry chimney.
  • Page 31: Mobile Home Installation

    MOBILE HOME INSTALLATION This appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home (U.S. only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 32: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 33: Framing

    5.0 FRAMING FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 34: Minimum Framing Dimensions

    5.1.1 MINIMUM FRAMING DIMENSIONS 34 3/4" 883mm 14 1/2" 368mm W415-1296 / A / 09.17.14...
  • Page 35 It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes. It is not necessary to install a hearth extension with this appliance. When roughing in the appliance, raise the appliance to accommodate for the thickness of the fi nished fl oor materials, i.e.
  • Page 36: Minimum Enclosure Clearances

    MINIMUM ENCLOSURE CLEARANCES TOP EXIT ENCLOSURE The appliance requires a minimum non-combustible enclosure height of 54" (1372mm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. W415-1296 / A / 09.17.14...
  • Page 37 REAR EXIT ENCLOSURE The appliance requires a minimum non-combustible enclosure height of 36" (914mm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed. * See "VENTING" section. W415-1296 / A / 09.17.14...
  • Page 38: Alcove Clearances

    ALCOVE CLEARANCES RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied. The minimum enclosure volume must be increased by no less than the volume of the recess.
  • Page 39: Minimum Mantel Clearances

    MINIMUM MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 40: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 41: Log Placement

    THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. 76.1A logs and glowing embers exclusive to Napoleon, provide a unique and realistic glowing effect that is PHAZER different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.
  • Page 42: Logo Placement

    Reinstall the door and safety screen. Place the right crossover log (W135-0579) onto the two remaining pins. LOGO PLACEMENT Remove the backing of the logo supplied and place on the glass viewing door, ½" (12.7mm) as indicated. LOGO ½" (12.7mm) 97.1A W415-1296 / A / 09.17.14...
  • Page 43: Battery Back-Up Installation

    BATTERY BACK-UP INSTALLATION NOTE: In the event of a power failure your appliance can be operated using the battery back-up supplied. Remove the safety screen by lifting it up and off of the four shoulder screws. Locate your battery holder, this would have been supplied in the manual baggie. Locate the red and black wires from the control module to connect to the battery holder, as shown below.
  • Page 44: Blower Installation

    BLOWER INSTALLATION WARNING ENSURE THE UNIT IS COMPLETELY COOL BEFORE STARTING INSTALLATION TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY. KNOT BEFORE THROWING AWAY.
  • Page 45: Wiring Diagram (Electronic)

    WIRING DIAGRAM (ELECTRONIC) A wall switch or remote control must be installed in a convenient location to operate the main burner. A 20’ (6.1m) length of 18 gauge wire is connected to the gas valve wire harness for this wall switch, however, if a greater length is required route 2-strand (solid core) wire complete with two 1/4”...
  • Page 46: Operation (Electronic)

    7.0 OPERATION (ELECTRONIC) WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 47: Operation (Millivolt)

    8.0 OPERATION (MILLIVOLT) WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 48: Adjustment

    9.0 ADJUSTMENT PILOT BURNER ADJUSTMENT Check Pressure Readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should readas described on the chart below. Check with main burner operating on “HI”.
  • Page 49: Flame Characteristics

    FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ames 3/8” - 1/2” appear abnormal call a service person. (9.5mm - 12.7mm) FLAME MUST ENVELOP UPPER 3/8"...
  • Page 50: Door Glass Replacement

    10.2 ANNUAL MAINTENANCE WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE. NEVER VACUUM HOT EMBERS. DO NOT PAINT THE PILOT ASSEMBLY. • This appliance will require maintenance which should be planned on an annual basis. •...
  • Page 51: Care Of Glass

    NEVER ALLOW CHILDREN discoloration and / or blemishes may result. TO TOUCH GLASS. This appliance is factory equipped with 4mm tempered glass. Use only replacement glass available from your Napoleon® dealer. DO NOT SUBSTITUTE MATERIALS. W415-1296 / A / 09.17.14...
  • Page 52: Replacements

    11.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. ** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
  • Page 53: Overview

    W415-1296 / A / 09.17.14...
  • Page 54: Millivolt Valve Train Assembly

    W415-1296 / A / 09.17.14...
  • Page 55: Electronic Valve Train Assembly

    W415-1296 / A / 09.17.14...
  • Page 56: Accessories

    W415-1296 / A / 09.17.14...
  • Page 57: Troubleshooting

    16.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 58 SYMPTOM PROBLEM TEST SOLUTION Carbon is being Air shutter has become Ensure air shutter opening is free of lint or other deposited on blocked. obstructions. glass, logs, Flame is impinging on the Check that the glass, logs, rocks or media are rocks, media glass, logs, rocks, media correctly positioned.
  • Page 59 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm Sulphur from fuel is being Clean the glass, see “CARE OF GLASS” section forms. deposited on glass, logs or DO NOT CLEAN GLASS WHEN HOT. combustion chamber If deposits are not cleaned off regularly, the glass surfaces.
  • Page 60: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 61: Service History

    18.0 SERVICE HISTORY 43.1 W415-1296 / A / 09.17.14...
  • Page 62: Notes

    19.0 NOTES 44.1 W415-1296 / A / 09.17.14...
  • Page 63 44.1 W415-1296 / A / 09.17.14...
  • Page 64 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gourmet Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 65 à risque. ÉCRAN DE PROTECTION N° de série N° DE MODÈLE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • ask@napoleon.on.ca 10,00$ 1.28D...
  • Page 66 TABLE DES MATIÈRES NOTE: L'icône du camera indique que les vidéos sont disponibles comme une référence supplémentaire, visitez http://www.napoleonfi replaces.com/category/product-support/support-centre/ VUE D'ENSEMBLE DE L'INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATIONS GÉNÉRALES INFORMATION À PROPOS DE LA PLAQUE D’HOMOLOGATION ÉVACUATION LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS INSTALLATIONS TYPIQUES D'ÉVENTS...
  • Page 67: Vue D'ensemble De L'installation

    1.0 VUE D'ENSEMBLE DE L'INSTALLATION Voir la section « DÉGAGEMENTS MINIMAUX DE L’ENCEINTE » pour les cloisons sèches (ou autre matériau combustible). Voir la section « DÉGAGEMENTS MINIMAUX DE LA TABLETTE ». Voir les sections « ÉVACUATION » et « INSTALLATION ». Voir la section «...
  • Page 68: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 69: Dimensions

    DIMENSIONS 12 3/4" 324mm 7" 34 1/2" 34 1/16" 178mm 876mm 866mm ÉCRAN DE PROTECTION 24 3/16" 4" 614mm 102mm 6 11/16" 170mm 8 5/8" 136mm 14" GAZ DU 1 15/16" ENTRÉE B30 ILLUSTRÉ 355mm 30" ENTRÉE 50mm DU GAZ 762mm W415-1296 / A / 09.26.14...
  • Page 70: Instructions Générales

    INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL. ASSUREZ-VOUS D'UNE QUANTITÉ SUFFISANTE D’AIR DE VENTILATION. N’OBSTRUEZ JAMAIS L’OUVERTURE DE L’APPAREIL.
  • Page 71: Informations Générales

    INFORMATIONS GÉNÉRALES POUR VOTRE SATISFACTION, CET APPAREIL A ÉTÉ MIS À L'ESSAI POUR CONFIRMER SON FONCTIONNEMENT ET SA QUALITÉ! RENDEMENTS ET EFFICACITÉS Altitude (PI) 0-4,500 0-4500 Débit max. (BTU/H) 15,000 15,000 Pression minimale 4.5" (11mb) w.c. 11" (27mb) w.c. d'alimentation en gaz Pression maximale 7"...
  • Page 72: Information À Propos De La Plaque D'homologation

    NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM. BACK / ARRIERE VENT BOTTOM / EVENT INFERIEUR 1" L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. MANTEL / MANTEAU 12" * REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST * MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2".
  • Page 73: Évacuation

    3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 74: Longueurs Des Conduits D'évacuation Et Composants

    LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimums et maximums des longueurs d’évent, pour les installations verticales et horizontales, et les emplacements des terminaisons pour les deux systèmes sont précisés dans ce manuel et doivent être respectés.
  • Page 75: Installations Typiques D'évents

    INSTALLATIONS TYPIQUES D'ÉVENTS 16" (406MM) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) MINIMUM 24" (610MM) MAXIMUM 8" (203MM) MINIMUM 42 1/16" (1068MM) MINIMUM PLUS LA 34 1/16" 34 1/16" PENTE* (865MM) (865MM) ÉVACUATION SUR LE DESSUS W415-1296 / A / 09.26.14...
  • Page 76 16" (406MM) MINIMUM 40 FT (12M) MAXIMUM 3 FT (1M) MINIMUM 20" (508MM) 24 3/16" 24 3/16" (614MM) (614MM) PLUS LA PENTE ÉVACUATION SUR L’ARRIÈRE * Voir la section « ÉVACUATION » W415-1296 / A / 09.26.14...
  • Page 77: Installations Particulières D'évents

    INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un minimum de 12 pouces (304,8mm) au-dessus du niveau du sol.
  • Page 78: Emplacements Et Dégagements Minimaux De La Terminaison

    EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON ††* APPLICATIONS POUR BALCON COUVERT INSTALLATION = 3 pieds = 2 x RÉELLE (0,9m) (4,6m) CANADA É.-U. 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. (304,8mm) (304,8mm) 12”...
  • Page 79: Charte D'application Des Évacuations

    CHARTE D'APPLICATION DES ÉVACUATIONS ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale est La course verticale est plus grande ou égale à est plus petite que la plus grande ou égale à est plus petite que la course horizontale.
  • Page 80: Légende

    LÉGENDE Les symboles suivants sont utilisés dans le calcul et les exemples d’évacuation : > - plus grand que > - plus grand ou égal à < - plus petit que < - plus petit ou égal à - total de la longueur des courses horizontales (Hr) et des déviations (Ho) en pieds - longueur des courses horizontales combinées en pieds - facteur de la valeur d’une déviation : 0,03 (du total des degrés de déviation - 90°*) en pieds - longueur des courses verticales combinées en pieds...
  • Page 81: Évacuation Sur Le Dessus Terminaison Horizontale

    ÉVACUATION SUR LE DESSUS TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 90° Consultez le graphique pour déterminer la course verticale seulement). nécessaire V par rapport à la course horizontale requise H 40 (12,2) 39 (11,9) 30 (9,1) COURSE VERTICALE REQUISE EN...
  • Page 82 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H (un coude de 90° seulement) 150 (3810) 147 (3733,8) COURSE VERTICALE 100 (2540) REQUISE EN POUCES (MILLMÈTRES)V 57 (1447,8) 50 (1270)
  • Page 83: Évacuation Sur Le Dessus Terminaison Verticale

    ÉVACUATION SUR LE DESSUS TERMINAISON VERTICALE ) < (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale nécessaire (deux coudes de 90° seulement) par rapport à la course horizontale requise H 40 (12,2) 38,3 (11,7) COURSE 30 (9,1) VERTICALE REQUISE EN PIEDS...
  • Page 84 ) > (V Configuration d'évacuation simple Consultez le graphique pour déterminer la course verticale (deux coudes de 90° seulement) nécessaire V par rapport à la course horizontale requise H 150(3810) 147 (3733,8) COURSE VERTICALE 100 (2540) REQUISE EN PIEDS (MÈTRES) V (1676,4) 50 (1270) 12 (304,8)
  • Page 85: Évacuation Sur L'arriére Terminaison Horizontale

    3.10 ÉVACUATION SUR L'ARRIÉRE TERMINAISON HORIZONTALE ) < (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE 20 (6,1) REQUISE EN PIEDS (MÈTRES) V 10 (3,1)
  • Page 86 ) > (V Consultez le graphique pour déterminer la course verticale Configurations d'évacuation simples. nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (1,5) (3,1) (4,6) (6,1)
  • Page 87: Évacuation À L'arrière

    Exemple : = 1,5 PI (0,5m) = 5 PI (1,5m) = 1,5PI (0,5m) + 5PI (1,5m) = 6,5 PI (2m) = 1 PI (0,3m) = 1 PI (0,3m) = 10,75 PI (3,3m) = 1PI (0,3m) + 1PI (0,3m) + 10,75PI (3,3m) = 12,75PI (3,9m) = 0,03 (quatre coudes 90°...
  • Page 88: Installation

    4.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 89: Installation Horizontale

    4.1.1 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. Cette confi...
  • Page 90: Utilisation De Composants Flexibles D'évacuation

    UTILISATION DE COMPOSANTS FLEXIBLES D’ÉVACUATION AVERTISSEMENT NE LAISSEZ PAS LA GAINE FLEXIBLE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE AVEC LE CONDUIT EXTÉRIEUR. POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE, UN ESPACE VIDE EST REQUIS.
  • Page 91: Installation De La Terminaison Verticale

    4.2.2 INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (50,8mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel.
  • Page 92: Utilisation De Composants Rigides D'évacuation

    UTILISATION DE COMPOSANTS RIGIDES D’ÉVACUATION Le système d’évacuation doit être soutenu à peu près tous les 3 pieds (0.9m) de courses verticales et horizontales. Utilisez l’ensemble de support mural Wolf Steel ou des supports incombustibles équivalents afi n de conserver le dégagement minimal aux matériaux combustibles pour les courses verticales et horizontales.
  • Page 93: Installation De La Terminaison Verticale

    4.3.2 INSTALLATION DE LA TERMINAISON VERTICALE Mettez l’appareil en place. CONDUIT Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit INTÉRIEUR est optionnel. Dans ce cas, l’évent doit être supporté adéquatement, soit en utilisant une méthode alternative se conformant aux normes des autorités compétentes, soit en utilisant le support de toit optionnel.
  • Page 94: Terminaison Verticale À Travers Une Cheminée Existante

    TERMINAISON VERTICALE À TRAVERS UNE CHEMINÉE EXISTANTE AVERTISSEMENT RISQUE D'INCENDIE! LES CONFIGURATIONS D'ÉVACUATION COAXIALES À COLINÉAIRES NE DOIVENT ÊTRE UTILISÉES QUE DANS UNE CHEMINÉE OU UNE ENCEINTE DE NATURE INCOMBUSTIBLE. UNE INSTALLATION DANS UNE ENCEINTE COMBUSTIBLE PEUT CAUSER UN INCENDIE. Cet appareil est conçu pour être raccordé...
  • Page 95: Installation Dans Une Maison Mobile

    INSTALLATION DANS UNE MAISON MOBILE Cet appareil est certifi é pour être installé comme équipement d’origine (OEM) dans une maison préfabriquée ou une maison mobile. Son installation doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons mobiles, CAN/CSA Z240 SÉRIE MH, au Canada.
  • Page 96: Branchement Du Gaz

    BRANCHEMENT DU GAZ AVERTISSEMENT RISQUE D'INCENDIE, D'EXPLOSION OU D'ASPHYXIE. ASSUREZ-VOUS QU'IL N'Y AIT AUCUNE SOURCE D'ALLUMAGE COMME DES ÉTINCELLES OU UNE FLAMME NUE. SOUTENEZ LE CONTRÔLE DU GAZ LORSQUE VOUS ATTACHEZ LE TUYAU POUR ÉVITER DE PLIER LA CON- DUITE DE GAZ. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 97: Ossature

    5.0 OSSATURE AVERTISSEMENT RISQUE D’INCENDIE! AFIN D’ÉVITER LA POSSIBILITÉ QUE DE L’ISOLATION OU UN COUPE-VAPEUR ENTRENT EN CON- TACT AVEC L’EXTÉRIEUR DU CAISSON, IL EST CONSEILLÉ D’INSTALLER L’APPAREIL CONTRE DES MURS FINIS (C.-À-D. PANNEAU DE GYPSE) COMME TOUT AUTRE MUR DE LA MAISON. CECI ASSURERA QUE LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES EST MAINTENU.
  • Page 98: Dimensions Minimales De L'ossature

    5.7.1 DIMENSIONS MINIMALES DE L’OSSATURE 34 3/4" 883mm 14 1/2" 368mm W415-1296 / A / 09.26.14...
  • Page 99 Il est préférable de construire l'ossature après que l'appareil est en place et que le système d'évacuation est installé. Construisez conformément aux exigences des codes du bâtiment locaux. Il n'est pas nécessaire d'installer une base de protection avec ce type d'appareil. Lorsque vous mettez l'appareil en place, surélevez-le de façon à...
  • Page 100: Dégagements Minimaux De L'enceinte

    DÉGAGEMENTS MINIMAUX DE L'ENCEINTE ENCEINTE AVEC ÉVACUATION SUR LE DESSUS L'enceinte de l'appareil doit avoir une hauteur minimale de 54" (1372mm). Afi n de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction. W415-1296 / A / 09.26.14...
  • Page 101 ENCEINTE AVEC ÉVACUATION À L'ARRIÈRE L'enceinte de l'appareil doit avoir une hauteur minimale de 36" (914mm). Afi n de respecter les contraintes de température, l’espace à l’intérieur de l’enceinte, autour de l'appareil et au-dessus, doit demeurer sans obstruction. * Voir la section « ÉVACUATION » W415-1296 / A / 09.26.14...
  • Page 102: Installation En Alcôve

    INSTALLATION EN ALCÔVE ZONE ENCASTRÉE OU ALCÔVE ZONE ENCEINTE APPAREIL NOTE : Les zones encastrées ou les alcôves au dessus de l'appareil peuvent être aussi profondes que désiré tant que les dégagements minimaux aux matériaux combustibles sont respectés. Vous pouvez utiliser un matériau incombustible, pourvu que les dégagements minimaux aux matériaux combustibles soient appliqués.
  • Page 103: Dégagements Minimaux De La Tablette

    DÉGAGEMENTS MINIMAUX DE LA TABLETTE AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ TOUS LES DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES SPÉCIFIÉS. NE PAS RESPECTER CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE SURCHAUFFE. ASSUREZ-VOUS QUE TOUS LES DÉGAGEMENTS (ARRIÈRE, CÔTÉS, DESSUS, ÉVENTS, TABLETTE, FAÇADE, ETC.) SONT RESPECTÉS À LA LETTRE. LORSQUE VOUS UTILISEZ DE LA PEINTURE OU DU VERNIS COMME FINITION POUR VOTRE TABLETTE, ASSUREZ-VOUS QU’ILS SOIENT RÉSISTANTS À...
  • Page 104: Finitions

    6.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. LA FAÇADE DE L’APPAREIL DOIT ÊTRE FAITE DE MATÉRIAUX INCOMBUSTIBLES COMME DE LA BRIQUE, DU MARBRE, DU GRANITE, ETC., À CONDITION QUE CES MATÉRIAUX NE SE TROUVENT PAS EN DEÇÀ...
  • Page 105: Disposition Des Bûches

    DISPOSITION DES BÛCHES AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 106: Mise En Place Du Logo

    Installez la porte et l’écran de protection. Placez la bûche croisé droite (W135-0547) en place par alignez les trous en bas de la bûche avec les deux tiges située dans la bûche droite et aux côté droite de la bûche inférieure.
  • Page 107: D'installation Du Sauvegarde De Pile

    D’INSTALLATION DU SAUVEGARDE DE PILE NOTE: En cas d’une panne de courrant votre appareil peut fonctionner utilisant le sauvegarde de pile fourni. Enlever l’écran de protection en le levant vers le haut hors des quatre vis d’épaulement. Trouver votre sauvegarde de pile, fourni aux sac du manuel. Localiser les fi...
  • Page 108: D'installation Du Soufflerie

    D’INSTALLATION DU SOUFFLERIE AVERTISSEMENT ASSUREZ-VOUS QUE L’APPAREIL EST COMPLÈTEMENT REFROIDI AVANT DE COMMENCER L’INSTALLATION . AFIN D’ÉVITER LES RISQUES DE SUFFOCATION, GARDEZ LE SAC D’EMBALLAGE LOIN DES BÉBÉS ET DES JEUNES ENFANTS. NE LE LAISSEZ PAS TRAÎNER DANS LES BERCEAUX, LES LITS, LES POUSSETTES OU LES PARCS DE JEU.
  • Page 109: Schéma De Câblage

    SCHÉMA DE CÂBLAGE Pour faire fonctionner le brûleur principal, il est nécessaire d’utiliser une télécommande ou d’installer un interrupteur mural dans un endroit pratique. Pour l’interrupteur mural, un fi l de calibre 18 d’une longueur de 20’ (6,1m) est branché au harnais de fi...
  • Page 110: Fonctionnement (Electronique)

    7.0 FONCTIONNEMENT (ELECTRONIQUE) AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POURRAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS,DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 111: Fonctionnement (Millivolt)

    8.0 FONCTIONNEMENT (MILLIVOLT) WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 112: Réglages

    9.0 RÉGLAGES RÉGLAGE DE LA VEILLEUSE Lecture des pressions : Pour vérifi er la pression d’arrivée, tournez deux ou trois fois la vis (A) vers la gauche, puis emboîtez le tube du manomètre sur la pointe d’essai. Le manomètre doit indiquer la pression comme décrit sur le diagramme ci- dessous.
  • Page 113: Caractéristiques De La Flamme

    CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, contactez un technicien de service. 3/8” - 1/2” (9,5mm - 12,7mm) LA FLAMME DOIT ENVELOPPER LA...
  • Page 114: Entretien Annuel

    10.1 ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. •...
  • Page 115: Remplacement De La Vitre De Porte

    10.2 REMPLACEMENT DE LA VITRE DE PORTE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX DE SUBSTITUTION. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DÉBRIS DE VERRE OU DES COMPOSANTS ENDOMMAGÉS.
  • Page 116: Rechanges

    11.0 RECHANGES AVERTISSEMENT OMETTRE DE POSITIONNER LES PIÈCES CONFORMÉMENT À CE MANUEL OU D’UTILISER UNIQUEMENT DES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. ** CECI EST UN THERMOCOUPLE À ACTION RAPIDE QUI CONSTITUE UN COMPOSANT ESSENTIEL DE SÉCURITÉ.
  • Page 117: Vue D'ensemble

    W415-1296 / A / 09.26.14...
  • Page 118: L'assemblage De La Soupape De Millivolt

    W415-1296 / A / 09.26.14...
  • Page 119: L'assemblage De La Soupape De Electronique

    W415-1296 / A / 09.26.14...
  • Page 120: Accessories

    W415-1296 / A / 09.26.14...
  • Page 121: Guide De Dépannage

    16.0 GUIDE DE DÉPANNAGE MAINTENANCE MAINTENANCE MAINTENANCE AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL.
  • Page 122 SYMPTÔME PROBLÈME SOLUTIONS Du carbone se Le volet d’air est bloqué. Assurez-vous que l’ouverture du volet d’air n’est pas bloquée par dépose sur la des fi bres ou autres obstructions. vitre, les bûches, Les fl ammes effl eurent la vitre, - Vérifi...
  • Page 123 SYMPTÔME PROBLÈME SOLUTIONS Une pellicule Le soufre du combustible Nettoyez la vitre avec un nettoyeur recommandé. NE blanche ou grise se dépose sur la vitre, les PAS NETTOYER LORSQU’ELLE EST CHAUDE. se forme. bûches ou les parois de la Si vous ne nettoyez pas les dépôts régulièrement, la chambre de combustion.
  • Page 124: Garantie

    17.0 GARANTIE Les produits Napoléon® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits Napoléon® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 125: Historique D'entretien

    18.0 HISTORIQUE D’ENTRETIEN 43.1 W415-1296 / A / 09.26.14...
  • Page 126: Notes

    19.0 NOTES 44.1 W415-1296 / A / 09.26.14...
  • Page 127 44.1 W415-1296 / A / 09.26.14...
  • Page 128 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...

This manual is also suitable for:

B30ptrB30ntreB30ptre

Table of Contents