Faults
Engine overheats
Malfunction indicator lamp
lights up yellow
Engine dies during the trip
ABS warning lamp lights up
Possible cause
Foam formation in cooling sys-
tem
Thermostat defective
Fuse 5 blown
Defect in radiator fan system
Malfunction in the electronic
fuel injection
Lack of fuel
Main fuse or fuse 3, 4 or 7
blown
ABS fuse blown
Large difference in wheel
speeds of the front and rear
wheels
Malfunction in ABS
TROUBLESHOOTING 21
Action
Drain the coolant.
(
p. 224)
Fill/bleed the cooling system.
(
p. 225)
Check the thermostat.
Change the fuses of individual power
consumers. (
p. 209)
Check the radiator fan system.
Read out the fault memory using the
Husqvarna Motorcycles diagnostics
tool.
Refuel. (
p. 105)
Change the main fuse. (
Change the fuses of individual power
consumers. (
p. 209)
Change the ABS fuses. (
Stop the vehicle, switch off the igni-
tion, and start it again.
Read out the ABS fault memory using
the Husqvarna Motorcycles diagnos-
tics tool.
p. 204)
p. 206)