Installation; Ats125X 4-Door Dgp Overview - GE ATS125 Series Installation Manual

4-door dgp
Table of Contents

Advertisement

Installation

ATS125x 4-door DGP overview

The figure below shows the 4-door DGP layout.
Figure 1: ATS125x layout
J1
~
CON1
~
+
-
+
CON2
-
+
-
S+
S-
+
-
+
CON3
-
NO
CON4
COM
NC
NO
COM
NC
NO
CON5
COM
NC
NO
COM
CON6
NC
0V D+ D- T
1.
DIP switches (see "DIP switch settings" on page 7)
2.
RAM or IUM (optional)
3.
EPROM (factory fitted)
4.
KILL jumper: Factory default ATS125x when
shorted
5.
Battery fuse F1
6.
Auxiliary power fuse F2
7.
Databus 1 fuse F3
8.
Databus 2 fuse F4
9.
Lock power 1 fuse F5
ATS125x 4-Door DGP Installation Manual
LK1
PTC1
K1
K2
F1
F2
F3
F4
F5
5
6
7
8
9
K3
K4
LK6
LK3
LK4
TERM1
TST1
TST2
TERM2
12
CON7
CON8
C
1
C
2
3
C
4
5
C
6
7
17
LK2
PTC2
4
LK10
KILL
RST
ATS125x
F6
F7
10
11
LK11
TST3
CON14
LK7
LK8
TERM3
INPUT EXPANDER
OUTPUT EXPANDER
16
13
14
15
CON9
CON10
C
8
10. Lock power 2 fuse F6
11. Siren / switch fuse F7
12. TERM 1: Use this link to terminate the system
databus
13. TERM 2: Use this link to terminate the local
databus, connection 1 on terminal CON9
14. TERM 3: Use this link to terminate the local
databus, connection 2 on terminal CON10
15. CON14 Input expander connector
16. CON15 Output expander connecter
17. Mains terminal
ADDRESS
MODE
1
IC13 RAM/IUM
2
3
IC6 EPROM
CON13
CON11
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ats1251Ats1252Ats1253Ats1254

Table of Contents