KEY FEATURES

Flexible and optimum system construction with standard Ethernet devices
Since the CC-Link IE TSN and the TCP/IP network can coexist, the standard Ethernet devices can be used on the same
line. This enables to perform control communications and information communications on the same Ethernet, reducing the
design and installation cost for the system construction. Even if various data communications are performed over the
network, the system control is not affected and the punctuality of control data can be ensured.
Ò
TCP/IP communications
Ó
Transient communications
Ô
I/O control communications
Ò
Ô
Standard
Remote I/O
Ethernet device
Easy replacement of slave stations using the
automatic parameter distribution function
Parameters stored in the CPU module by the master station
are automatically distributed to the slave stations when the
slave station is powered ON or disconnected stations return
to the network. This eliminates the need of writing
parameters individually to each slave station even after
replacement, facilitating replacement of the slave stations.
Automatically distributing the parameters to slave stations
Automatically distributing the parameters to slave stations
and changing the currently-set parameters
and changing the currently-set parameters
Slave station
Replacement
Replacement
6
Ô
Inverter
Programmable controller
Parameters saved in the CPU module
Slave station
Slave station
100
50
Ó
0
Link scan time ratio [%]
Easy debug of the entire network
Parameters of all stations can be set and monitored by
connecting GX Works3 to any one of the ports in the CC-
Link IE TSN network. This eliminates the need of rewiring
cables, reducing the debug cost.
Master station
Data can be transferred
Data can be transferred
Data can be transferred
by connecting to
by connecting to
by connecting to
the built-in Ethernet port
the built-in Ethernet port
the built-in Ethernet port
of the CPU module.
of the CPU module.
of the CPU module.
Slave station
For a setting example when GX Works3 is connected to P1 connector of the
FX5-CCLGN-MS, refer to Page 29 Operation Check of the Local Station.
Network line load Image
P1 connector of
FX5-CCLGN-MS
Remote
I/O station
Local station
Information
communication
bandwidth
ÒÓ
(
)
Control
communication
bandwidth
Ô
(
)
Time
Code
reader

Advertisement

Table of Contents
loading

Table of Contents