Alarm Function; Specifications - Sony SSM-Q177 Service Manual

Black and white quad monitor
Hide thumbs Also See for SSM-Q177:
Table of Contents

Advertisement

MENU Operation

Alarm Function

Connect external sensors to ALARM IN connectors on the
rear panel of the monitor. Alarm signal input from external
sensors will trigger a display of a picture on the channel in
which the alarm signal was received. The monitor will send
out alarm signal output that will trigger visual recording on
a device such as a Time-Lapse VCR.
Alarm state
When an alarm signal comes through ALARM IN
connector, the monitor enters an alarm state described
below.
• A buzzer that indicates an alarm state will sound. (Only
when you have selected BUZZER ON on the menu.)
• A lamp on the channel button will start flashing.
• The monitor will show on full screen a picture of the
channel that received the alarm signal and a sign that says
ALARM. If two or more channels received the alarm
signal, the monitor will show a quad display, and the
pictures of the channels that received the alarm signal will
have a letter A on the display.
• ALARM OUT TRG connector will send out an alarm
trigger signal for 100ms at LOW voltage.
• The alarm signal output sent out from the ALARM OUT
connector turns to ON (LOW).
16

Specifications

General
System
CCIR standard
Picture tube 17-inch picture measured diagonally
90-degree deflection
Resolution
More than 850 TV line (horizontal)
Camera input/VCR in
Composite: 1 Vp-p, sync negative; 75Ω
terminated
Video output/VCR out
Composite: 1 Vp-p, sync negative; 75Ω
terminated
Clock error range
Less than 60 sec/month
Power requirements
230V AC, 50/60 Hz
Power consumption
Approximately 45 W
Operating temperature
0°C to +35°C (32°F to 95°F)
Operating humidity
0% to 90% (no condensation)
Operating pressure
700 hpa to 1,060 hpa
Storage temperature
–10°C to +40°C (14°F to 104°F)
Storage humidity
0% to 90%
1-18
Termination of the alarm state
To terminate the alarm signal, press the channel button of
the channel that received the alarm signal. When the alarm
time that is set on the menu is elapsed, the alarm state will
terminate itself automatically. When the alarm state is
terminated, the monitor enters a state described below.
• The buzzer will stop.
• The lamp on the channel button will go off.
• The ALARM sign or A sign on the monitor will disappear.
• The monitor will show quad display.
• The alarm signal output sent out from the ALARM OUT
TRG connector turns to OFF (HIGH).
Alarm I/O signal
5V
ALARM IN
Falling edge triggers alarm
5V
ALARM OUT
Alarm set time
5V
ALARM
TRIGGER OUT
–0V
100ms
Storage pressure
700 hpa to 1,060 hpa
Dimensions 424 × 409 × 380 mm (w/h/d)
× 16
× 15 inches)
(16
3
/
1
/
4
8
Mass
Approx. 18.8 kg (41 lb 7 oz)
Supplied Accessory
Operating Instructions (1)
Optional Accessory
Mounting Bracket RMM-171
Design and specifications are subject to change without
notice.