NEC Aspila Topaz Programming Manual page 152

Intelligent hybrid system
Hide thumbs Also See for Aspila Topaz:
Table of Contents

Advertisement

Program 20: System Option Setup
20-12
: Class of Service Options (Charging Cost Service)
Description
Use Program 20-12 : Class of Service Options (Charging Cost Service) to define the Charging Cost feature
availability for each extension's Class of Service.
Input Data
Class of Service Number
Prog. No.
20-12-02
Advice of Charge (ISDN-AOC)
20-12-03
-Not used-
*All Classes are above mentioned default value.
Conditions
None
Feature Cross Reference
Class of Service
Telephone Programming Instructions
To enter data for Program 20-12(Class of Service Options(Charging Cost Service)):
1. Enter the programming mode.
2. Enter 20 12
20-12-01 F-Cls1  
Advice Charge 0
3. Enter the number of the item you want to program.
20-12-xx F-Clsxx
xxxxx
4. Select the Class of Service number to be programmed by pressing the FLASH or the VOLUME
VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Programming Manual
Item
144
01-15
Input Data
Default*
1
0 : Off
1 : On
-
or
IN
SA
SB
Related
Program
-

Hide quick links:

Advertisement

Table of Contents
loading