Connection - Bosch Rexroth PS5000 Commissioning And Operating Instructions

Operating and diagnostic terminal
Hide thumbs Also See for Rexroth PS5000:
Table of Contents

Advertisement

3−4
Bosch Rexroth AG
Assembly and Connection
3.1.2

Connection

Electric Drives
and Controls
To operate, the BT 6.190 requires not only the power supply to X1 but
also communication connection X2 (RS 232 c; connection to X1 of the
weld timer).
Positions of the individual connections:
X1:
power supply input
X2:
communication with the weld timer (RS 232 c).
For communication with a PC (download of BT firmware) if
bootstrap mode is active
X3:
not assigned
PE:
threaded bolt for connection to PE conductor
S1:
flush key for activating bootstrap mode
The control terminal may be connected and disconnected when the ti-
mer is switched on.
Communication with the control is usually established automatically
when the X2 is attached if the BT 6.190 power supply (X1) was interrup-
ted earlier.
If the BT 6.190 power supply (X1) was not interrupted earlier, the BT
6.190 reports that the connection to the weld timer can not be establis-
hed. In this case, simply press key
munication.
The BT 6.190 has been designed, and is therefore especially suita-
.
ble, for spot seam controls.
If an unsuitable control is connected, the device reports "Incorrect
SST type!", including the connected control type, when the con-
nection is established.
BT 6.190
Type label
X2
X3
X1
PE
S1
on the BT 6.190 to establish com-
1070087068 / 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth ps6000Rexroth bt 6.190

Table of Contents