Table 5-7 lists the test conditions and results of the reliability of the MC509 module.
Table 5-7 Test conditions and results of the reliability of the MC509 module
Item
Low-temperature
storage
High-temperature
storage
Low-temperature
working
High-temperature
working
Damp heat cycling
Temperature shock
Salty fog test
Issue 02 (2013-05-06)
Standby current consumption with Sleep mode deactivated-Idle (assumes USB bus is fully
suspended during measurements).
The above values are the average of some test samples.
Test Condition
Temperature: –40º C± 2º C
Test duration: 24 h
Temperature: 85º C± 2º C
Test duration: 24 h
Temperature: –30º C± 2º C
Test duration: 24 h
Temperature: 75º C± 2º C
Test duration: 24 h
High temperature: 55º C± 2º C
Low temperature: 25º C± 2º C
Humidity: 95%
Repetition times: 4
Test duration: 12 h+12 h
Low temperature: –40º C± 2º C
High temperature: 85º C± 2º C
Temperature change interval: < 30s
Test duration: 15 min
Repetition times: 100
Temperature: 35º C
Density of the NaCl solution: 5%± 1%
Spraying interval: 8 h
Duration of exposing the module to
the temperature of 35º C: 16 h
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Standard
IEC60068
IEC60068
IEC60068
IEC60068
IEC60068
IEC60068
IEC60068
55