Bosch Rexroth ID 40 Manual page 78

Table of Contents

Advertisement

78/176
Interbus
Bosch Rexroth AG, MIT: ID 40, 3 842 530 344/2014-05
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy
No.
PCP
Index
communication
2
Wait until actual link state in process data channel is CONNECTED
4
Read MDT status
0x5FF5
and check if
error bits are
present
5
Read data from
0x5FF5
MDT, e.g., 32
bytes as of ad-
dress 0x0110
6
Write data to
0x5FF5
MDT, e.g., 50
bytes as of ad-
dress 0x0100
8
Close MDT
Via process data channel:
(RECONNECT)
Byte 0: 0x03 (switch trigger bit: now 0, used to be 1)
9
Wait until actual link state in process data channel is CONNECTED
Subindex 0
Subindex 1
Subindex 2
0x00020000
0x0001
0x00000110
0x0020
0x00000100
0x0032
Subindex 3
Read data
Read data
Byte1 Byte2 ...
Write data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents