Functions - Breville the AirDynamic 3D Connect Instruction Book

Table of Contents

Advertisement

o

Functions

MODE
This Breville AirDynamic 3D™ Connect air
circulator has 4 modes: NORMAL, TURBO,
NATURAL and SMART ECO. The air
circulator will start automatically on NORMAL
mode on speed 1 once it is switched on.
NORMAL MODE
NORMAL mode has 8 fan speed settings;
setting 1 for lowest fan speed up to setting 8 for
the highest fan speed. To choose a fan speed,
touch the
or
buttons until the desired
speed number is reached and the speed will
adjust automatically.
NORMAL mode is the default mode settings
for this air circulator. In NORMAL mode, none
of the buttons NATURAL, SMART ECO or
TURBO illuminate on the control panel.
TURBO MODE
TURBO mode creates extra comfort on a hot
day. On TURBO mode, the air circulator will
run at the highest speed (8) automatically.
Touch the
button and the light will
illuminate to indicate it is activated.
NATURAL MODE
Continuous air flow can create a chilling
effect on the skin and a discomfort when
exposed for too long. NATURAL mode
generates a gentle breeze to maintain body
temperature, by simulating a wind blowing
rhythm, automatically alternating wind speeds
according to pre-programed cycles. NATURAL
mode has 3 variations.
When the unit is on, to activate NATURAL
mode, touch the
button. The light will
illuminate on the NATURAL button on the
control panel and the default NATURAL cycle
program 1 (n1) will display on the LED display.
The fan speed will operate automatically
according to the natural cycle 1 (n1) program.
12
To select NATURAL cycle program 2 (n2) and
NATURAL cycle program 3 (n3), touch the
button and 'n2' and 'n3' will display respectively.
To stop NATURAL mode and return to
NORMAL mode, touch the
button until no
lights illuminate on the NATURAL button on
the control panel.
Diagram showing NATURAL cycle programs:
Program 1 (n1)
7
4
1
OFF
Program 2 (n2)
7
4
1
OFF
Program 3 (n3)
7
4
1
OFF
1 = Low speed, 4 = Medium speed, 7 = High speed
SMART ECO MODE
SMART ECO mode will automatically adjust
the fan speed depending on the ambient room
temperature. This program delivers the optimal
cycle to save energy and operate quietly and
efficiently, when possible. SMART ECO mode
is ideal to use during sleep or when left on for a
long period of time.
When the unit is on, to activate SMART ECO
mode, touch the
button and the light will
illuminate on the button.
The air circulator will automatically adjust
the fan speed based on the following
programmed rules.
Ambient T (°C) Air circulator speed
< 26
Speed 1
26 – 28
Cycle between speed 2,
speed 3 and speed 4.
Operation for 5 secs
on each speed.
29 – 34
Cycle between speed 5,
speed 6 and speed 7.
Operating for 5 secs on
each speed.
> 35
Speed 8
n
NOTE:
Fan speed in this mode cannot be manually
adjusted.
To stop SMART ECO mode and return to
NORMAL mode, touch the
button until no
light illuminates on the button.
AUTO-OFF TIMER
The Breville Air Circulator comes with a
12-hour auto-off timer that can be set in one-
hour intervals. To set the timer, press the
button until the desired hour is displayed on
the display screen. Once the timer icon stops
flashing, the timer will be set. The timer will
start on the selected mode, and the selected
speed and will stop automatically once the
time has elapsed.
To set the timer, press the
button repeatedly
until the desired number of hours is displayed
on the LED display. Light flashes on the
TIMER button on the control panel during
setting and the light flashing will stop when
timer is set.
The auto-off timer will start on the selected
mode and will stop automatically once the
time has elapsed. The LED display will display
the set circulator mode once the auto-off timer
begins. To check the pre-set time left on the
LED display, touch the
button once.
n
NOTE:
The display will revert back to the current room
temperature. To display the remaining time,
press the TIMER button once.
To cancel the auto off time anytime, press
the
button until '0' is displayed on the
LED display and the green light above the
TIMER button no longer illuminates within a
few seconds.
n
NOTE
• To run the air circulator continuously, do not
set the timer or set the timer to '0'.
• All modes can be adjusted at any time after
the timer is set.
• The air circulator will stop and switch to
standby mode once the set time has elapsed.
OSCILLATION AND
3D AIR CIRCULATION
The Breville Air Circulator can oscillate left to
right and up and down. The oscillations can be
set on any MODE.
To activate the left to right oscillation, touch
the
button once. The air circulator will move
left to right continuously.
To activate the up and down oscillation, touch
the
button once. The air circulator will start
to move up and down continuously.
To achieve 3D air circulation, activate both
horizontal and vertical oscillations. This will set
a unique air circulation pattern.
When the air circulator is turned off, it returns
to its initial position automatically.
To set the orientation of your air circulator,
touch the respective oscillation button
again. The oscillator will stay at your
preferred position.
13