Blade Guard - Makita DLS713 Nstruction Manual

Cordless slide compound miter saw
Hide thumbs Also See for DLS713:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Battery protection system (Lithium-
ion battery with star marking)
► Fig.8: 1. Star marking
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically
cuts off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the trigger switch on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
trigger switch again to restart.
If the tool does not start, the battery is over-
heated. In this situation, let the battery cool
before pulling the trigger switch again.
Low battery voltage:
The remaining battery capacity is too low
and the tool will not operate. In this situation,
remove and recharge the battery.
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
► Fig.9: 1. Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Indicator lamps
Lighted
Off
NOTE: Depending on the conditions of use and the
ambient temperature, the indication may differ slightly
from the actual capacity.
Remaining
capacity
Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery
may have
malfunctioned.

Blade guard

► Fig.10: 1. Blade guard
When lowering the handle, the blade guard rises auto-
matically. The guard is spring loaded so it returns to
its original position when the cut is completed and the
handle is raised.
WARNING:
Never defeat or remove the blade guard or
the spring which attaches to the guard. An
exposed blade as a result of defeated guarding
may result in serious personal injury during
operation.
In the interest of your personal safety, always maintain
the blade guard in good condition. Any irregular opera-
tion of the blade guard should be corrected immediately.
Check to assure spring loaded return action of guard.
WARNING:
Never use the tool if the blade guard or
spring are damaged, faulty or removed.
Operation of the tool with a damaged, faulty or
removed guard may result in serious personal
injury.
Cleaning
► Fig.11: 1. Blade guard
If the transparent blade guard becomes dirty, or saw-
dust adheres to it in such a way that the blade and/or
workpiece is no longer easily visible, remove the battery
cartridge and clean the guard carefully with a damp
cloth. Do not use solvents or any petroleum-based
cleaners on the plastic guard because this may cause
damage to the guard.
For cleaning, raise the blade guard by referring to
"Installing or removing saw blade".
After cleaning, make sure to return the blade and center
cover and tighten the hex socket bolt.
1.
Make sure that the tool is switched off and the
battery cartridges are removed.
2.
Turn the hex socket bolt counterclockwise using
the supplied hex wrench with holding the center cover.
3.
Raise the blade guard and center cover.
4.
When cleaning is complete, return the center
cover and tighten the hex socket bolt by performing the
steps above in reverse.
WARNING:
blade guard. If guard becomes damaged in course
of time or UV light exposure, contact a Makita ser-
vice center for replacement. DO NOT DEFEAT OR
REMOVE GUARD.
Positioning kerf board
► Fig.12: 1. Thumb screw 2. Kerf board
► Fig.13: 1. Saw blade 2. Blade teeth 3. Kerf board
4. Left bevel cut 5. Straight cut
This tool is provided with the kerf boards in the turn
base to minimize tearing on the exit side of a cut. The
kerf boards are factory adjusted so that the saw blade
does not contact the kerf boards. Before use, adjust the
kerf boards as follows:
15 ENGLISH
Do not remove spring holding

Advertisement

Table of Contents
loading

Table of Contents