EXCEL 500/600 - INSTALLATION INSTRUCTIONS
Sensors and Transducers
Table 16. Sensors suitable for use with Excel 500/600 (external transducer not required)
sensor type
AF20 Outside Air Temperature Sensor
VF20A Strap-On Temperature Sensor
KTF20 Boiler Temperature Sensor
LF20 Duct Temperature Sensor
AQS51 or C7110C1001 CO
C7110A1005 Air Quality (Mixed Gas) Sensor
T7560C1006 Combined Room Temp. / Humidity Sensor
or H7012B1023 Room Humidity Sensor
Table 17. Room Temperature Sensors suitable for use with Excel 500/600 (external transducer not required)
sensor type
T7460A1001 Room Temperature Sensor
T7460B1009 Room Temperature Sensor
TF22 Room Temperature Sensor
T7460C1007 Room Temperature Sensor
T7460E1002 Room Temperature Sensor
T7460F1000 Room Temperature Sensor
T7460A1000 Room Temperature Sensor
T7460C1006 Combined Room Temperature / Humidity
Sensor
C7110D1009 Combined Room Temperature / Humidity
Sensor
T7560B1008 Combined Room Temperature / Humidity
Sensor
*supported in AH03
Table 18. Humidity Sensor suitable for use with Excel 500/600 (external transducer not required)
sensor type
H7015B1020 Duct Humidity Sensor
H7508A1042 Outside Humidity Sensor
EN1R-1047GE51 R0913
Sensor
2
range
-20...+30° C
0...+110° C
0...+100° C
-30...+100° C
0...2000 ppm CO
2
0...100%
6...40°C
20...95% relative humidity
range
6...40°C
setpoint wheel
6...40°C
setpoint wheel
operating knob
6...40°C
setpoint wheel
occupancy button*
6...40°C
setpoint wheel
occupancy button*
fan speed, 3 stages
6...40°C
setpoint wheel
occupancy button*
fan speed, 5 stages
6...40°C
setpoint wheel
occupancy button*
fan speed, 5 stages
6...40°C
20...95% r.h.
6..40°C
0...2000 ppm CO
2
setpoint wheel
occupancy button*
6...40°C
20...95% r.h.
setpoint wheel
occupancy button*
fan speed, 5 stages
characteristic in controller
(set using CARE)
0..10 V = 0...100%
30
characteristic in controller
(set using CARE)
NTC
0...10 V = 0..2000 ppm
0...10 V = 0...100%
NTC
0..10 V = 0...100%
characteristic in controller
(set using CARE)
NTC
linear input
NTC
linear input
-
NTC
linear input
-
NTC
linear input
-
NTC
linear input
-
NTC
linear input
-
NTC
0..10 V = 0...100%
NTC
0..10 V = 0...2000 ppm
linear input
-
NTC
0...10 V = 0...100%
linear input
-
additional remarks
set jumper to 0...10 V