4-2-4. Aperture Diameter Brush Pattern Check (Iris Pattern)
Equipment
• Personal Computer
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of "ActuatorChecker".
[Set up]
3)
Click
2. Checking Method
[Iris Pattern]
1)
Click the
2)
The Serial window appears. Input the lens serial number.
Note:
When
item.
Fig.4-2-19
3)
The message "Move IRIS to [A]. Then push [ENTER]." is displayed on the pop-up window.
Set the iris to the
SAL135F28 (STF 2.8(T4.5)/135) (135mm F2.8 [T4.5] STF)
, and perform the initial setting. (Refer to Section 4-1-4.)
.
Fig.4-2-18
[OK]
is clicked without inputting the serial number, the date executed is displayed on the completion window of each
[A]
position and press down the ENTER key.
Fig.4-2-20
4-21