TROUBLESHOOTING
SYMPTOM
Alarms when no one is walking
through the detection area.

COMPONENT IDENTIFICATION

Pole
Bracket
CAUSE
Sensor is not perpendicular to ground.
Sensor is detecting moving trees,
bushes, or a strong source of light.
Lower detection area is too long.
A heat source in the area may be
causing an abrupt temperature
change.
Back Box
M4 x 30 (4 places)
Mounting Screws
T4 x 20
DIP Switch
Sensitivity Select
Switch
Lens
Lens
Holder
REMEDY
Remount and align sensor so the detection area is parallel to
the ground.
Check for moving trees, or bushes or a strong light source.
Perform a Settings & Adjustments procedure.
Set Detection Length to a shorter range.
Move or remove the heat source.
Mask the area pointing to the source of heat, or shorten the
Detection Length.
Detector
Sensor
(Do not touch)
Detection Length