Download Print this page

Honeywell 5800-OD Installation Instructions Manual page 3

Wireless outdoor motion sensor

Advertisement

5800-OD Wireless Outdoor Motion Sensor – Installation Instructions
Press and slide the Detection Length Adjustment Switch to the desired position.
D
C
B
A
SET THE DETECTION AREA ANLGLE
1.
The detection area angle is 90° with 7
fingers as shown.
45
o
90
o
45
IF NECESSARY, CONFIGURE DETECTION MASKING
1.
Spread the Cover and gently press on the
Lens to remove the Lens Holder.
5.
Replace the Lens by aligning the 4 cutouts
on the lens to the 4 projections on the cover.
Snap in place with the Lens Holder.
Cover
Lens
POSITION
D
C
B
A
Detection length may vary due to environmental conditions.
Detection height = 1m (3.3ft)
Top view
12
10
o
5
0
5
10
12
(m)
0
2.
Separate the Lens from the Cover.
Lens
Holder
3.
Identify the segments on the Lens to be masked.
6.
Ensure the Lens Holder is held by the left and
right cover prongs and the two tabs are engaged.
MAX DETECTION LENGTH
STANDARD
ENVIRONMENTAL
02.0m (6.7ft)
1.5 - 2.5m (5 - 8ft)
05.0m (16.7ft)
04 - 5.5m (13 - 18ft)
08.0m (26.7ft)
06 - 10m (20 - 33.3ft)
12.0m (40.0ft)
10 - 15m (33.3 - 50ft)
o
45 Adjustable
Active detection
fingers.
o
45 Adjustable
5
10
12
(m)
Cover
Lens
Area Masking
Plate
Lens
Holder
3
2.
Hold the sensor and turn it to the desired
direction. Each click represents 15° of
change.
Adjust to
desired direction
4.
Then apply the adhesive Masking
Strip(s), as necessary, inside the
lens to cover the desired
segments.
5
4
3
2
1
1
2
3
4
5
Cover
7
6
8
9
10
11
12
13
6
7
8
9 10
11
12
13

Advertisement

loading