(84) Receive section and line layer event status register (SSLER)
This register indicates the current status of each event.
Register
Name
Port0:
SSLER
01F0
31
30
29
28
15
14
13
12
Reserved
Bit
Field
D31-D12
Reserved
Reserved
SD
D11
1: SD event in progress
SF
D10
1: SF event in progress
CD
D9
1: The CD input is low.
Reserved
Reserved
D8
D7
PSBF
1: PSBF event in progress
LRDI
D6
1: Line RDI event in progress
LAIS
D5
1: Line AIS event in progress
STIU
D4
1: Section TIU event in progress
D3
STIM
1: Section TIM event in progress
LOF
D2
1: LOF event in progress
OOF
D1
1: OOF event in progress
LOS
D0
1: LOS event in progress
Note: the default value of this register is depends on input level of the CD pin.
CHAPTER 5 REGISTERS
Address
Port1:
Port2:
Port3:
05F0
09F0
0DF0
27
26
25
24
Reserved
11
10
9
8
SD
SF
CD
Res
PRELIMINARY
Access
Default
R
Note
23
22
21
20
7
6
5
4
PSBF
LRDI
LAIS
STIU
Function
0: SD event is not detected.
0: SF event is not detected.
0: The CD input is high.
0: PSBF event is not detected.
0: Line RDI event is not detected.
0: Line AIS event is not detected.
0: Section TIU event is not detected.
0: Section TIM event is not detected.
0: LOF event is not detected.
0: OOF event is not detected.
0: LOS event is not detected.
NEC confidential and Proprietary
Function
Read-only
19
18
17
16
3
2
1
0
STIM
LOF
OOF
LOS
Default
All 0
0
0
Note
Note
0
0
1
0
0
1
1
0
251