WRITERS NOTE: LEVELING FEET?
Outdoor Locations
Location of a water treatment system is important. The following
conditions are required:
Level platform or floor
Room to access equipment for maintenance and adding regenerant
(salt) to tank.
Ambient temperatures over 34F (1C) and below 120F (49C).
Water pressure below 120 psi (8.27 bar) and above 20 psi
(1.4 bar).
In Canada the water pressure must be below 100 psi (6.89 bar).
Constant electrical supply to operate the controller.
Total minimum pipe run to water heater of ten feet (three meters) to
prevent backup of hot water into system.
Local drain for discharge as close as possible.
Water line connections with shutoff or bypass valves.
Must meet any local and state codes for site of installation.
Valve is designed for minor plumbing misalignments. Do not support
weight of system on the plumbing.
Be sure all soldered pipes are fully cooled before attaching plastic
valve to the plumbing.