38 | FWA 4630 | Operation
4 .12

Plate size selection

i
The standard plates for passenger vehicles can be
used for measuring wheelbases of up to max. 3400
mm.
i
For wheelbases in excess of 3400 mm, use must be
made of the large commercial vehicle plates at the
rear axle for measurement purposes.
Fig. 18:
Wheelbase/sensor spacing
L
Sensor spacing - front axle
VA
L
Sensor spacing - rear axle
HA
L
Wheelbase
R
L
[mm]
L
[mm]
R
VA
1900 – 3500
Pass. vehicles
max. 1750
3500 – 4300
Pass. vehicles
max. 1750
|
1 690 706 005
2011-05-11
4 .13
i
The front of the plate must face the sensor.
Fig. 19:
1 Socket pin
2 Clamping screw
1. Lightly lubricate the socket pins of the plates to pro-
tect the pin and socket.
L
[mm]
HA
Pass. vehicles
max. 1750
Comm. vehicles
Fig. 20:
1750 – 2850
2. Attach the four plates to the clamps.
i
The plates can be attached to the clamp in any order.
3. Use the spirit level (1) to align the plates.
Fig. 21:
1 Spirit level

Attachment of plates

Front view of plate
Rear view of plate
Plate spirit level
Robert Bosch GmbH