Zenith HYDROTAP 30009 Installation And Operating Instructions Manual

Filtered boiling and chilled drinking water for kitchens and tea rooms

Advertisement

Zenith HydroTap
Filtered boiling and chilled drinking water for kitchens and tea rooms.
Commercial Models
37671 Zenith HydroTap BC60/85
30271 Zenith HydroTap BC100/125
30281 Zenith HydroTap BC150/175
37201 Zenith HydroTap B10OF
38201 Zenith HydroTap B150F
37691 Zenith HydroTap B60
37291 Zenith HydroTap B100
38291 Zenith HydroTap B150
Disabled Models
37676 Zenith HydroTap BCD60/85
37276 Zenith HydroTap BCD100/125
38286 Zenith HydroTap BCD150/175
37206 Zenith HydroTap BD10OF
38206 Zenith HydroTap BD150F
37696 Zenith HydroTap BD60
37296 Zenith HydroTap BD100
38296 Zenith HydroTap BD150
81467 - February 2005
Installation and Operating Instructions
®
Domestic models
30009 Zenith HydroTap HT60
30609 Zenith HydroTap HTD60
36051 Zenith HydroTap HT60/85
36651 Zenith HydroTap HTD60/85
37606 Zenith HydroTap BFD60 (Ambient)
37601 Zenith HydroTap BF60 (Ambient)

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HYDROTAP 30009

  • Page 1 37296 Zenith HydroTap BD100 38296 Zenith HydroTap BD150 81467 - February 2005 ® Domestic models 30009 Zenith HydroTap HT60 30609 Zenith HydroTap HTD60 36051 Zenith HydroTap HT60/85 36651 Zenith HydroTap HTD60/85 37606 Zenith HydroTap BFD60 (Ambient) 37601 Zenith HydroTap BF60 (Ambient)
  • Page 2: Table Of Contents

    Warranty Information .......24 NOTE: All plumbing must comply with AS3500.4.1 & AS3500.4.2 All electrical must comply with AS3350.1, AS3350.2.15 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005...
  • Page 3: Read These Warnings First

    Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Read These Warnings First Safety Do not allow young children, handicapped or infirm persons, to use the Zenith HydroTap without supervision. Refrigerant The Zenith HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the unit should be exposed to a naked flame.
  • Page 4: Models Covered By These Instructions

    • Power supply 220-240 Volt AC, for connection to the heater via a 10 amp G.P.O. Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 continued Weight empty Weight full kg’s lbs...
  • Page 5: Special Tools Required

    Smear silicon on underside flat surface Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Installation Requirements • This switch must provide all-pole disconnection and a contact separation of at least 3mm installed in accordance with wiring rules.
  • Page 6: Step B - Installing The Undersink Unit (All Models)

    Before positioning the heater connect the braided water inlet hose (supplied) to the cold water inlet on the unit. This is located at the rear of the unit. Position the Zenith HydroTap undersink unit as close as possible to directly beneath the Zenith HydroTap tap head.
  • Page 7: Step D - Connecting The Water Supply (All Models)

    Blue Light Boiling Filter Status Chilled Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Installation procedure continued Step D - Connecting the water supply (all models) To prevent sediment from entering the Zenith HydroTap at connection, flush water through the supply line thoroughly before connection to the Zenith HydroTap.
  • Page 8: Font Installation Procedure

    Font must have constant fall 9. Connect the Tap head Assembly supply hoses and vent as per the instructions contained in the installation procedure section of this document. Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005...
  • Page 9: Operating The Tap

    20 minutes.When the chilled water is ready, the light will stop flashing. Note: The Zenith HydroTap is designed to dispense chilled water in the temperature range 5°C to 10°C. During heavy usage, the temperature can rise out of this range.
  • Page 10: Cleaning

    After approx 10 secs it will default to the selected mode. Warning: If the Zenith HydroTap is switched off for a long period of time, e.g. longer than a weekend, run water through the chilled water outlet for at least 5 minutes before consumption.
  • Page 11: Setting The Energy Saver Timer

    Mode Plus Button Mode Minus Button Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Setting the Energy Saver Timer Normal Operation (not available on HT boiling only series) Set Time To change time, press either Mode ∧ or Mode ∨ button until Set Time is on the display screen.
  • Page 12: Auxilliiary Fan Attachment

    7. If de-activation mode is required, de-activate by scrolling through the menu and selecting de-activate when Hot Isolation Mode is displayed on the screen. Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 (excluding HT boiling only models) (excluding HT boiling only models)
  • Page 13: Trouble Shooting

    Water not chilled. Excessive use, unit refilling or chilling down to temperature. Possible internal fault. Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Trouble Shooting Solution Check power supply. Ensure power plug is correctly fitted and switch is turned ON.
  • Page 14: Exploded View Chiller Module And Spares

    Z90652 transformer kit-auxillary fan Z90657 second solenoid boiling only model Z90041 38mm chassis punch Z90671 3ag-10amp fuse Z90670 2ag-2amp fuse Z90669 2ag-1amp fuse Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Description braided hose...
  • Page 15: Exploded View Boiler Module And Spares

    Z90623 transformrer kit Z90624 leak sensor kit Z90625 control panel kit Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Exploded View Boiler Module and Spare Parts Item Kit No. Z90130 Z90628 stop valve and john guess fittings kit for filter...
  • Page 16 Clips Kit Flexible Inlet Hose Kit Level Sensor Kit Hot Tank H/T 60/85 Loom-Overload Kit Loom-Solenoids Kit Loom-Level Sensor Kit Hot Loom and Gland Main PCB to Tap Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005...
  • Page 17 Notes Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Page 17 of 20...
  • Page 18 Notes Page 18 of 20 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005...
  • Page 19 Notes Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005 Page 19 of 20...
  • Page 20: Warranty Information

    No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zenith Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair its Distributor.

Table of Contents