Panel Event Descriptions

The following table lists the events generated by the control/communicator. These events appear in the control/
communicator log by name and in the pager display by event number.
Event
Event
#
01
AC Fail
02
AC
Restore
03
Alarm,
Tamper
04
Alarm,
Emergency
05
Alarm,
Panic
06
Alarm,
Invisible
07
Alarm,
24-hr.
Burg
08
Alarm,
Cntrl, Dly
09
Alarm,
Cntrl
10
Cross,
Tamper
11
Cross,
Emergency
12
Cross,
Panic
13
Cross,
Invisible
14
Cross,
24-hr.
Burg
Cross,
15
Cntrl, Dly
16
Cross,
Cntrl
17
Cross,
Unverified
18
Alarm Exit
Error
19
Alrm
Recent
Clse
20
Alrm
Recent
Clse
21
Auto On
Extended
22
Battery
Low
23
Battery
Missing
© 2003 Bosch Security Systems
Description
AC power to panel interrupted.
AC power to panel restored.
Alarm from detection device tampered
with.
Alarm from emergency detection device
or ABC key programmed for emergency
response.
Alarm from panic/emergency detection
device.
Alarm from detection device that does
not appear at command center during
alarm or trouble conditions.
Alarm from burglary detection device
on 24 hours per day.
Alarm from detection device with
entry/exit delays.
Alarm from detection device such as
keyswitches, motion detectors
(followers), or devices that initiate an
alarm immediately (do not follow any
entry/exit delays).
Tamper alarm from detection device
with Cross Point option selected.
Emergency alarm from detection device
with Cross Point option selected.
Panic alarm from detection device with
Cross Point option selected.
Panic alarm from invisible detection
device with Cross Point option selected.
Burglary alarm from detection device
with Cross Point option selected.
Alarm from entry/exit detection device
with Cross Point option selected.
Alarm from keyswitch, follower, or
instant detection device with Cross
Point option selected.
Fault on one non-fire point type with
Cross Point option selected. This is not
an alarm event.
Detection device faulted at end of exit
delay.
Alarm event within 2 min. of closing.
Alarm event within 2 min. of closing.
Auto On sked delayed 1 hr. by user.
Report follows Open/Close routing.
Panel backup battery is low.
Panel backup battery missing. Very low,
shorted, or open batteries reported as
missing.
D623/D625 User Guide
Event
Event
Description
#
24
Rstrl Batt
Battery restoral from low battery.
Low
25
Rstrl Batt
Battery restoral from missing battery.
Missing
26
Bypass,
Selective bypass by user of fire detection
Fire, User
device.
27
Bypass,
Selective bypass of fire detection device
Fire,
by RAM IV.
RAM IV
28
Bypass,
Selective bypass by user of controlled
Ctrl, User
detection device.
29
Bypass,
Selective bypass by RAM IV of
Ctrl,
controlled detection device.
RAM IV
30
Bypass,
Selective bypass by user of 24-hr. non-
24-hr,
fire detection device.
User
31
Bypass,
Selective bypass by RAM IV of 24-hr.
24-hr.,
non-fire detection device.
RAM IV
32
Bypass,
Detection device force-armed
Forced Pt
33
Bypass,
Point swinger bypassed.
Swinger
34
UnBypass,
User cleared bypass (unbypass) of fire
Fire, Usr
detection device.
35
UnBypass,
User cleared bypass (unbypass) of
Ctrl, Usr
controlled detection device.
36
UnBypass,
User cleared bypass (unbypass) of 24-
24-hr., Usr
hr. detection device.
37
Call For
Report sent automatically at Call For
Service
Service interval. Does not indicate a
trouble condition.
Cancel
User acknowledged active alarm before
38
Alarm
bell time expired for non-fire detection
device.
39
Cancel
User acknowledged active alarm before
Fire
bell time expired for fire detection
device.
40
CheckSum
Checksum on panel parameters failed.
Fail
Contact security company to verify
panel program.
41
CheckSum
Checksum on SDI device parameters
Fail, SDI
failed. Contact security company.
42
Cls, All,
System turned All On with entry/exit
+Dly, Skd
delay by sked.
43
Cls, All,
System turned All On with entry/exit
+Dly, KS
delay by keyswitch.
44
Cls, All,
System turned All On with entry/exit
+Dly,
delay by
RAM IV
RAM IV.
45
Cls, All,
System turned All On with entry/exit
+Dly, Tel
delay by telephone.
46
Cls, All,
System turned All On with no delay
-Dly, Usrl
(instant) by user.